Example of rating plate AquaPanel
AquaPanel
Type designation
380-415V 50/60Hz
Voltage
Manufacturer,
SULZER Pump Solutions Ireland Ltd. Wexford, Ireland
address
Applications
Follow the starting and operating instructions supplied with the pump.
NOTE! Always protect the AquaTronic control panel so that no
moisture will penetrate into the enclosure. Do not place the Aqua-
Tronic control panel on the ground.
Protection according to NEMA Enclosure 4, 4x (IP65).
c
AquaTronic control panel shall always be removed from
power supply prior to service on panel.
c
Before service on pump, power must be disconnected and
locked at AquaTronic control panel.
c
Only open the enclosure while it is disconnected from
power.
Start sequence AquaPanel
1. Make sure you have a XJ, XJC or XJS pump equipped with an AquaTronic
unit (from now on called "pump").
2. If pump is not connected, open lid on panel, make sure power is discon-
nected and connect pump cable in accordance with connection diagram.
(Fig. 1)
3. Connect AquaTronic control panel and pump to power supply.
4. After approximately 1 seconds, pump shall start running.
5. Green button shall flash under a short period telling that AquaPanel is
paring with the pump.
6. Green buttons turns constantly green when paring is done.
7. You can ensure that connection to the correct pump is done by stopping
pump with red button and observe that pump stops pumping, then turn
pump back on running by pressing green button.
8. If pump has been running with the same AquaPanel before, it will remain
in pump status as when it was disconnected.
AquaTronic control panel
AquaPanel
Gr
To pump
Figure 1.
Wiring diagram AquaTronic control panel
Installation Guide
Original instructions
2015
Year of
manufacture
Snr: 000001
Serial number
L1
L2
L3
T1
T2
T3
Power in
The manufacturer reserves the right to change the design and specifications.
Pairing
The AquaPanels have a built in memory of which pump they were paired to
last time, this is done to ensure that the units will find the correct pumps if a
power failure occurs on more than one pump in an installation.
There are two time outs in the system.
1. Pairing time out: Which means that if pairing does not occur in one min-
ute, the AquaPanel will not continue to search for a pump. This is done to
ensure that the unit will not pair with and control a "foreign" pump.
2. Power time out: This means that a pump will not pair with a unit which has
been powered a shorter time than itself. This is done to ensure that the
AquaPanel takes control of the pump it was plugged in with.
Technical data
Ambient operating temperature
Ambient storage temperature
Material
A
B
Degree of protection
Power supply
Power consumption
Max current
Input voltage
Flame rated
Maximum length of I/O cables
Approval
Dimensions
The AquaTronic control panel can be mounted on the wall using the four
screw holes, it can also be hung using the center hole on the mounting
bracket. (Fig. 2)
A 275 (B 278) mm
A 10 13/16" (B 10 15/16")
235 mm
9 1/4"
Figure 2.
Dimensions AquaTronic control panel and mounting bracket.
3
EN
0 to 40 ºC / 0 to 104 ºF
0 to 20 ºC / 0 to 68 ºF
Polyester GF
Polycarbonate
Nominal 4.4 x (IP 65)
See pump rating plate
See pump rating plate
See pump rating plate
See pump rating plate
UL746C 5V
100 m / 109 yards
CSA
A 165 (B 225) mm
A 6 1/2" (B 8 7/8
")