Descargar Imprimir esta página

RAV 635.1 SI Manual Del Usuario página 88

Elevador electrohidráulico

Publicidad

8
8. PROBLEMS
Some possible problems which may arise while using the lift are listed below. Ravaglioli will not accept any responsibility for damage to people, animals and
objects caused by unauthorised staff using the equipment. In the event of faults, you are advised to contact the technical service department in good time to
receive advice about how to carry out work and/or adjustments in maximum safety conditions, thus avoiding the risk of damage to people, animals and objects.
Turn the main switch to "0" and lock in case of emergency and/or maintenance to the lift
PROBLEMS
Lift does not work at all.
The lift elevates but does not drop.
Descent is extremely slow
The motor turns over regularly but
lifting does not take place.
The motor turns over regularly but
the rise speed is extremely slow.
The lift cannot lift the nominal
capacity
Non-synchronized platform
movement.
The release cylinders do not work.
The main lift and lift table elevate at
the same time.
ON button of the clearance test
pressed, but nothing happens.
The clearance test does not work
(light on).
With the clearance test OFF, the
light does not come on when the
MODE button is pressed.
Clearance test operation button is
pressed but the plates do not move
correctly.
OFF button pressed, the clearance
test or the light are not disabled.
88
CAUSES
a)
Main switch in "0" position
b)
Transformer fuse or general protection fuses
interrupted (installed by the user).
Fault in the electric system.
c)
a)
The safety pressure gauge is engaged due to
obstacles under the platform.
b)
Safety pressure gauge damaged or malfunction of
the control system.
Defect in the descent solenoid valve.
c)
d)
Fault in interception solenoid valve
e)
Descent control valve blocked.
a)
The capacity adjusting valve does not work properly.
a)
Descent control valve blocked in opening position.
b)
Pump suction filter blocked.
a)
Descent solenoid valve partially open.
b)
Pump suction filter partially blocked.
Pump worn or damaged.
c)
Faulty calibration valve.
a)
b)
Pump worn or damaged.
a)
Faulty alignment valve.
Worn gaskets in hydraulic cylinders.
b)
Release solenoid valve does not work properly.
a)
Release cylinder gasket worn or damaged.
b)
Interception valve does not work properly
a)
a)
Main switch in "0" position.
Transformer fuse or general protection fuses broken
b)
(installed by the user).
Fault in the electrical system.
c)
d)
Fault in the electronic card.
Fault in the keyboard.
e)
a)
Fault in the electronic card.
b)
Solenoid valve EV6 blocked in closing position.
Main switch in "0" position.
a)
b)
Transformer fuse or general protection fuses broken
(installed by the user).
c)
Fault in the electrical system.
Fault in the electronic card.
d)
e)
Fault in the keyboard.
Lamp interrupted.
f)
Fault in the keyboard.
a)
b)
Fault in the electronic card.
c)
Solenoid valve EV7 blocked.
a)
Fault in the keyboard.
b)
Fault in the electronic card.
0587-M001-0
TECHNICAL SERVICE REQUIRED
do not attempt to do the job yourself
a)
Turn switch to position "I".
b)
Replace the interrupted fuses. If it breaks again,
identify the cause.
Check efficiency, connections and components
c)
(buttons, remote control, heat detector, transformer).
a)
Press the up button until the platforms reach
mechanical stop. Remove the obstacles.
b)
To complete the descent press the descent button
insert the pin A inside the control unit.
To lower the platforms, proceed as in section 6.
c)
d)
To lower the platforms, proceed as in section 6.
e)
Dismantle and clean.
a)
See "Maintenance" section.
a)
See "Maintenance" section.
b)
Clean the filter
a)
See "Maintenance" section.
b)
Clean the filter.
Replace the pump.
c)
Request assistance from retailer's technical service.
a)
b)
Check that the pump is working properly and replace
if necessary.
a)
Check that the tap R (Fig.28) is closed. Clean the
valve if necessary and proceed as described in
section 4.9.
Replace the gaskets.
b)
Check that the spool of the solenoid valve is working
a)
properly and clean the solenoid valve.
Replace the gaskets.
b)
Clean or replace.
a)
a)
Place switch to position "1".
Replace interrupted fuses. If a fuse breaks again,
b)
find out the cause.
Check that connections and components works
c)
properly (buttons, remote switch, heat switch,
transformer).
d)
Replace electronic card.
Replace keyboard.
e)
a)
Replace electronic card.
b)
See "Maintenance" section.
Place switch to position "1".
a)
b)
Replace interrupted fuses. If a fuse breaks again,
find out the cause.
c)
Check that connections and components works
properly (buttons, remote switch, heat switch,
transformer).
Replace electronic card.
d)
e)
Replace keyboard.
Replace lamp.
f)
Replace keyboard.
a)
b)
Replace electronic card.
c)
See "Maintenance" section.
a)
Replace keyboard.
b)
Replace electronic card.
RAV640.1 - 640.2 - 640.3 - 640.3.46 - 640.4 - 640.4.46 - 640.5 - 640.6 (SI/ISI)
RAV650.1 - 650.2 - 650.3 - 650.4 - 650.5 - 650.6 (SI/ISI)
REMEDIES
RAV635.1 - 635.2 - 635.3 - 635.4 (SI/ISI)

Publicidad

loading