FAULTS
Excessive smoke from exhaust.
Inadequate detergent suction.
Water leakage from head.
Water in the oil.
N.B. To reset the indicators on the control panel, rotate the main switch "A" (fig. 7) to the "O" position and then to the
For maintenance and/or repairs, use only original spare parts which offer the greatest characteristics of quality and
reliability. Failure to use original spare parts frees the manufacturer from all responsibility.
English
CAUSES
Incorrect combustion.
Fuel contaminated with impurities or
water.
Tap closed.
No detergent.
Element or tube clogged.
Gaskets worn.
Excessive humidity in atmosphere.
"I" position.
IMPORTANT:
- 26 -
REMEDIES
Clean or replace diesel filters.
Contact Service Centre.
Empty the tank and clean thoroughly.
Clean diesel filters.
Open.
Fill the detergent tank.
Contact Service Centre.
Contact Service Centre.
Replace oil.