INSTALLATION INSTRUCTIONS
C-WM-A-MWP Series
WALL MOUNTED WITH CONDUIT FEED
1. Remove front assembly from the back mounting plate by removing
(4) screws, two screws on each side of the mounting plate. See
Figure 1.
2. For attachment of mounting plate to the mounting surface, drill out
chosen knockouts in the back of the mounting plate. See Figure 2.
NOTE: Center plug in mounting plate should not be removed when
using surface conduit.
3. Attach mounting plate to mounting surface using hardware supplied
by others.
NOTE: A high grade caulking material, such as silicone rubber,
should be used around the perimeter of gasket on back surface of
mounting plate (between gasket and mounting surface) to prevent
water leakage into luminaire.
NOTE: The bubble level on the mounting plate can be used to
ensure the mounting plate is mounted level.
4. Remove chosen threaded plug on the side of the mounting plate
and thread conduit into mounting plate.
NOTE: Teflon tape should be used on threads of conduit to achieve
a watertight seal.
5. Make wiring connections between the lead wires from the
front assembly and the supply leads per the ELECTRICAL
CONNECTIONS section.
6. Reattach the front assembly to the back mounting plate using the
(4) screws removed in Step 1. See Figure 3.
NOTE: Ensure the gasket between the front assembly and
mounting box is properly seated and that no lead wires are pinched
when tightening screws.
NOTE: Do not overtighten screws to avoid damage to front
assembly.
7. To control the photocontrol operation and to set the desired CCT,
access the dip switches by removing the conduit plug on the front
face of the fixture. Position dip switches to chosen settings.
See Figure 4.
NOTE: Dip switches are factory set at 4000K and photocontrol is
set to "ON".
FIGURE 4
Conduit Plug
http://lighting.cree.com/warranty
Document:
LPN00880X0001A0_A
Created By:
TMT
ELECTRICAL CONNECTIONS
Fixture is equipped with universal volt driver 120-277V
(ie. 120V, 208V, 240V or 277V)
PHASE TO NEUTRAL WIRING 120/277V
1. Connect supply ground to fixture ground (green) lead.
2. Connect supply common to fixture neutral (white) lead.
3. Connect supply Vin to fixture hot (black) lead.
Tuck all wires carefully into wiring chamber ensuring that no
wires are pinched.
PHASE TO PHASE WIRING 208/240V
1. Connect supply ground to fixture ground (green) lead.
2. Connect supply L1 (Hot) to fixture neutral (white) lead.
3. Connect supply L2 (Hot) to fixture hot (black) lead.
Tuck all wires carefully into wiring chamber ensuring that no
wires are pinched.
DIMMING
1. Pink and violet leads are for 0-10V dimming systems.
Cap off if not used.
2. For dimming connections, use Class 1 wiring methods.
FCC NOTICE
CAUTION: Changes or modifications not expressly approved could void
your authority to use this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area
is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
CAN ICES-005 (A)/NMB-005 (A)
|
1-800-236-6800