Service menu
ONLY QUALIFIED PERSONNEL CAN ACCESS THE SERVICE MENU AND MODIFY PARAMETERS.
The card Service Menu is accessed by pressing the Reset button for 10 seconds.
The display will show: "100" and the message "co" flashing.
Then set "103" with the DHW buttons, with the heating buttons set "123" and confirm by pressing the Reset button.
5 submenus are available: press the Heating buttons to select, in increasing or decreasing order, "tS", "sC", "In", "Hi" or "rE".
To enter the selected menu, press the reset button once.
"tS" - Transparent Parameters Menu
Press the Heating buttons to scroll the list of parameters in increasing or decreasing order. Press the DHW buttons to
view or modify the value of a parameter: the change will be automatically saved.
Contents Description
b01
Boiler type selection
b02
Exchanger type
Absolute Maximum Heating Power (b02=1)
Absolute Maximum Heating Power (b02=2)
b03
Absolute Maximum Heating Power (b02=3)
Absolute Maximum Heating Power (b02=4)
b04
System water pressure protection selection
b05
DHW mode
Variable input contact operation selection (b01=1)
Variable input contact operation selection (b01=2)
b06
Variable input contact operation selection (b01=3)
Variable input contact operation selection (b01=4)
Relay card LC32 operation selection (b01=1)
Relay card LC32 operation selection (b01=2)
b07
Relay card LC32 operation selection (b01=3)
Relay card LC32 operation selection (b01=4)
Hours without DHW drawn (b01=1)
No effect on adjustment (b01=2)
b08
Hours without DHW drawn (b01=3)
No effect on adjustment (b01=4)
b09
Fault 20 status selection
174
BLUEHELIX TECH RRT 24 H
Range
1=RRP, 2=RRH, 3=RRT, 4=RRK
1 ÷ 4
0-100% (Do not modify the value)
0-100% (Do not modify the value)
0-100% (Do not modify the value)
0-100% (Do not modify the value)
0=Pressure switch, 1=Pressure transducer
0 = Enabled, 1 = Disabled
0=Flowmeter off, 1=System thermostat, 2=Sec-
ond room thermostat, 3=Warning/Notification,
4=Safety thermostat
0=Continuous Comfort, 1=System thermostat,
2=Second room thermostat, 3=Warning/Notifica-
tion, 4=Safety thermostat
0=Flowmeter off, 1=System thermostat, 2=Sec-
ond room thermostat, 3=Warning/Notification,
4=Safety thermostat
0=Continuous Comfort, 1=System thermostat,
2=Second room thermostat, 3=Warning/Notifica-
tion, 4=Safety thermostat
0=External gas valve, 1=Alarm, 2=System load-
ing solenoid valve, 3=solar 3-way valve, 4=Sec-
ond heating pump, 5=Alarm2, 6=Burner On,
7=Frost protection active.
0=External gas valve, 1=Alarm, 2=System load-
ing solenoid valve, 3=Legionella pump, 4=Sec-
ond heating pump, 5=Alarm2, 6=Burner On,
7=Frost protection active.
0=External gas valve, 1=Alarm, 2=System load-
ing solenoid valve, 3=solar 3-way valve, 4=Sec-
ond heating pump, 5=Alarm2, 6=Burner On,
7=Frost protection active.
0=External gas valve, 1=Alarm, 2=System load-
ing solenoid valve, 3=solar 3-way valve, 4=Sec-
ond heating pump, 5=Alarm2, 6=Burner On,
7=Frost protection active.
0-24 hours (time for temporary deactivation of
comfort mode without drawing)
0-24 hours (time for temporary deactivation of
comfort mode without drawing)
0-24 hours (time for temporary deactivation of
comfort mode without drawing)
0-24 hours (time for temporary deactivation of
comfort mode without drawing)
0=Deactivated, 1=Enabled (Only for versions
with pressure transducer)
cod. 3541C660 - Rev. 01 - 05/2018
Default
2=RRH
2
83%
85%
85%
90%
0=Pressure switch
0 = Enabled
2=Second room therm.
2=Second room therm.
2=Second room therm.
2=Second room therm.
0=External gas valve
0=External gas valve
0=External gas valve
0=External gas valve
24 hours
24 hours
24 hours
24 hours
0=Deactivated