BLUEHELIX TECH RRT 24 H
Exchanger insulation replacement
•
Disconnect the power supply and close the gas tap upstream of the valve.
•
Remove the cover of the heat exchanger and the burner (see fig. 41).
•
Pull out the electrode "1".
•
Rotate the insulating disc "2" and remove it.
Fan
2
•
Disconnect the power supply and turn off the gas cock ahead of the valve.
•
Remove the connector from the fan
•
Remove the clamp "1" and undo the screws "2".
•
Remove the fan electrical connections and then the fan.
EN
3
2
1
3
fig. 42
cod. 3541C660 - Rev. 01 - 05/2018
1
187