Descargar Imprimir esta página

Ferroli BLUEHELIX TECH RRT 24 H Instrucciones De Uso, Instalación Y Mantenimiento página 199

Ocultar thumbs Ver también para BLUEHELIX TECH RRT 24 H:

Publicidad

Idiomas disponibles

Idiomas disponibles

BLUEHELIX TECH RRT 24 H
Attention: Remove the jumper on the terminal block before connecting the room thermostat or the remote
A
timer control.
To connect multiple zones of the plumbing system controlled by thermostats with voltage-free contact and
there is a need to use the timer control as a function of remote boiler controls, it is necessary to connect the
voltage-free contacts of the zones to terminals 1-2 and the timer control to terminals 5-6.
ALL CONNECTIONS TO THE TERMINAL BLOCK MUST BE WITH VOLTAGE-FREE CONTACTS (NOT
230V).
EN
X08-10
X08-11
X01-1
X01-2
X07-1
X07-2
X04-5
X04-7
X04-6
X08-8
X08-9
X05-1
X05-2
X05-3
X05-4
X01-4
X01-7
X01-6
X01-5
X01-3
X08-4
X08-5
X08-1
X08-2
fig. 57- Wiring diagram
cod. 3541C660 - Rev. 01 - 05/2018
X04-2
199

Publicidad

loading