Cleaning, Care & Maintenance; Troubleshooting; Technical Specifications - Buffalo DM869 Manual De Instrucciones

Sous vide
Ocultar thumbs Ver también para DM869:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
Cleaning, Care & Maintenance
Switch off and disconnect from the power supply before cleaning.
Disconnect from power by removing the plug, allow to cool before wiping exterior surfaces and
removing any loose debris.
Unit should be regularly descaled using a food safe descaler.

Troubleshooting

Fault
Appliance does not
heat
No power
Slow to Heat
Error message E01 is
displayed
LCD Display does not
switch on

Technical Specifications

Model
Voltage
DM869
230V 50Hz
DM869_ML_A5_v6_20190829.indb 5
Probable Cause
No power
Power switch is set to OFF
Auto re-set activated
Unit needs descaling
Water level is too low
Power switch is set to OFF
Power
Current
620W
2.8A
Solution
Make sure the appliance is plugged in
correctly
Set the power switch to ON
This product is fitted with a thermal
protector. Allow unit to cool for 30-45
minutes
Descale the appliance
Add water, making sure the water level is
between the MIN and MAX line
Set the power switch to ON
Dimensions
(h x w x d mm)
280 x 415 x 260
UK
Weight
7.5kg
5
2019/8/29 13:18

Publicidad

Tabla de contenido
loading

Tabla de contenido