2) Connect the welding cable to the connection marked with "-" and twist the cable plug to secure the
connection.
3) Connect the output gas line of the TIG torch to the connector on the front panel of the machine.
4) Connect the TIG torch control cable to the connector on the front panel of the machine.
5) Connect the gas inlet hose to the shielding gas cylinder equipped with a pressure reducer.
6) Connect the gas inlet hose to the gas inlet connection on the back of the machine. Slowly open the valve on
the gas cylinder and set the gas flow to the required value. Check for gas leaks.
7) Connect the power cord and turn on the power.
8) Connect the ground wire to the workpiece. Once these steps are completed, welding can begin.
8. Operation of the device
8.1.
Language setting
The welder offers several language options, so the operator can choose the preferred language.
8.2.
Setting the welding mode
Press the
(right) or
the next step (or press the knob).
8.3.
Automatic mode
In the automatic mode, it is possible to select the material and its thickness. Then it is possible to start welding as the
device will propose the welding current.
Note: If the material and thickness are set again, the system will revert to its default settings.
(left) button or turn the knob to select the desired welding mode. Then press
to go to