12. LUBRICATION MACHINE (See Fig. L)
The machine is grease-lubricated. A grease refill is only
required during hammer work efficiency is low. Open
the grease box lid at the top of the hammer using the
pin spanner provided. Then refill approx 30g grease
provided with your tool. The grease specification is
general purpose lithium based. Use only Worx genuine
hammer grease (optional accessory).
CAUTION: Keep the container of grease away
from children.
13. TO REPLACE THE BRUSHES (See Fig. M, N)
Disconnect the plug from the power supply.
Unscrew the carbon brush cap with screwdriver.
Remove the carbon brush. Check the length of the
brush and replace if under 6mm. When brushes need
replacement always renew both brushes, even if one is
still more than 6mm long.
Completely screw down the carbon brush cap. Check
that the tool is working. Before use, allow it run for a
few minutes to enable the brushes to settle.
WORKING HINTS FOR YOUR
TOOL
1. Reduce the pressure on the drill bit when it is about
to break through. This will prevent the drill from
jamming.
2. When drilling a large hole, first drill a pilot hole
using a smaller drill bit.
3. Always apply pressure to your drill bit in a
straight line, and if possible at right angles to the
workpiece.
4. Never change the operating mode whilst the drill is
running.
5. Do not apply excessive pressure to the tool when
chiseling. Expressive force does not speed up the
work.
MAINTENANCE
Remove the plug from the socket before carrying
out any adjustment, servicing or maintenance.
There are no user serviceable parts in your power
tool. Never use water or chemical cleaners to clean
your power tool. Wipe clean with a dry cloth. Always
store your power tool in a dry place. Keep the motor
ventilation slots clean. Keep all working controls free
of dust. Occasionally you may see sparks through the
ventilation slots. This is normal and will not damage
your power tool.
If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
Rotary hammer
TROUBLESHOOTING
1. If your power tool does not start, check the plug on
the power supply first.
2. If your hammer becomes too hot in use, set the
hammer switch to the drill mode and allow your drill
to operate at maximum speed without load for 2
minutes.
3. If your hammer work efficiency is too low, please
add sufficient grease in the grease box.
4. If your hammer use in low efficiency, please check
whether the tool is blunt.
5. If a fault can not be rectified, return the tool to an
authorized dealer for repair.
ENVIRONMENTAL
PROTECTION
Waste electrical products should not be
disposed of with household waste. Please
recycle where facilities exist. Check with your
Local Authority or retailer for recycling advice.