Installation Requirements
In Preparation
1.
Before cutting the opening in the countertop, verify that there will be no conflict between the rangetop
chassis and anything in the cabinet below.
2.
Remove all packing material and accessories from the rangetop, and verify that all items are present before
beginning the installation.
Location Requirements
Before you begin the installation, review this section thoroughly. These dimensions must be met for safe
operation. Location of the electrical outlet and gas piping may be adjusted to meet the specified parameters.
CAUTION
The rangetop complies with the maximum allowable wood-cabinet temperature of 194 °F (90 °C).
Ensure the wall covering, countertops, and surrounding cabinets can withstand this temperature to avoid
discoloration, delamination, or melting.
Maintain These Minimum Clearances
INSTALL_TOP_DTT48T960_DG68-01476A-00_EN+MES+CFR.indb 13
INSTALL_TOP_DTT48T960_DG68-01476A-00_EN+MES+CFR.indb 13
1. Vertical to combustible surface from
rangetop grate level; if installing a
ventilation hood, check hood spec's for
minimum required clearances.
2. See Cabinet/Countertop Dimensions
-Top View.
3. This specification is not applicable for
cabinets more than a horizontal distance
of 10" (25.4 cm) from the edge of the
rangetop.
Rangetop
DTT36*960
A
36" (91.44 cm)
36" (91.44 cm)*
B
42" (106.7 cm)**
* Minimum
** Recommended
A: Rangetop cutout
B: Range hood cutout
DTT48*960
48" (121.9 cm)
48" (121.9 cm)*
54" (137.2 cm)**
English 13