Checking for Gas Leaks
WARNING
To prevent an explosion/fire hazard possibly leading to personal injury or death, DO NOT use a flame to check
for gas leaks. When using pressures above 1/2 psig to test the home gas-supply system, disconnect the rangetop
and individual shut-off valve from the supply line. When testing with pressures of 1/2 psig or less, isolate the
rangetop by closing the individual shut-off valve.
1.
When all connections are made, ensure all rangetop controls are OFF, and turn on the main gas- supply valve.
2.
Use a liquid leak detector at all joints.
3.
Tighten connections as needed to prevent gas leakage in the rangetop or supply line.
Making the Electrical Connections
WARNING
•
Disconnect power at the main circuit breaker or fuse box before making electrical connections.
BEFORE operating/testing, follow the grounding requirements (pg. 20) of this manual. Improper connection
•
of the grounding plug is an electric-shock risk.
•
The electrical system (including power cord) is factory-installed/-wired. Altering any part of this system may
cause a short or overload.
1.
Plug in the power cord. (Ensure the outlet meets all applicable electrical codes; See Pg. 20.)
2.
After installing the rangetop, check the gas-supply line to verify it was not damaged and remains connected.
Assembling the Rangetop Burners
CAUTION
•
Do not operate the rangetop burners without all burner parts in place.
•
To avoid electric shock, do not:
-
push in any burner controls while removing the burner.
-
remove the top or touch the electrode of any burner while another burner is on.
INSTALL_TOP_DTT48T960_DG68-01476A-00_EN+MES+CFR.indb 23
INSTALL_TOP_DTT48T960_DG68-01476A-00_EN+MES+CFR.indb 23
1.
Place the burner heads on their bases (see left).
The electrodes fit in the slot in the bottom of the
heads, which should lie flat.
2.
Place the caps on their respective burner heads.
English 23
2022-11-24 오후 2:03:03
2022-11-24 오후 2:03:03