Descargar Imprimir esta página

Johnson MANANTIAL Serie Manual De Instrucciones página 25

Ocultar thumbs Ver también para MANANTIAL Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

D. Operation panel instruction
1. Panel - Operation:
Remark:
Set water temperature.
1.
Press TIMER for over 2 seconds to enter water temp. setting status, when the setting tem. value flashes, use
water temp.
ECON MODE (timer heating)
2.
There are 3 timer periods (P1, P2, P3) available for setting, they can only be set under ECON MODE.
AUTO MODE
3.
According to the setting water temperature value to control the unit ON/OFF. Timer period setting is invalid under this
mode.
HEATER MODE
4.
According to the setting water temperature value to control the unit ON/OFF (auxiliary heater forced to operation). Timer
period setting is invalid under this mode.
DELAY PROTECTION
5.
When the machine restart power on, there are 3 minutes time delay protection, it's 3 minutes interval between the unit start
and stop. At this time, on the screen it will display HTG and flash until the unit starts operation.
DISPLAY SCREEN
Displays the working mode, status, water temperature, time, etc.
ON/OFF BUTTON
Turn ON or OFF the unit by this button.
When the unit is turn ON, display screen shows HTG (heating), DEF
(defrost) or Warm (keep warm). When the unit is turned off, display screen
shows OFF.
MODE BUTTON
Press this button to switch to ECON mode (Economic mode) AUTO MODE
(Automatic mode) or HEATER MODE.
ECON MODE can only be set during selected the timer period to control the unit
operation, it will not control the unit any other time. AUTO MODE is according to
the setting water temperature to control the unit operation.
HEATER MODE is according to the setting water temperature (with auxiliary
heater function) to control the unit working.
* HEATER MODE can be selected and displayed only for the unit with auxiliary
heater models.
CLOCK BUTTON
Press this button to adjust the clock. When the corresponding time Hour
or Minute flashing, use the
TIMER BUTTON
Press this button for 2 seconds, enter temperature setting. When temp. value
flashes, use
button to adjust setting temperature. Press this button, enter
ECON MODE timer period for time setting status. There are 3 timer periods
beginning and ending for setting; when the time hour or minute value flashes,
use the button to adjust the corresponding time.
NOTE: Timer period setting is only available under ECON MODE.
UP/DOWN BUTTON
In standby mode, press
(up) to check the ambient temperature of the unit.
Press
(down) to check the condenser coil temperature. Under the
corresponding operation, use
or parameter data, etc.
6
button to adjust.
to adjust the water temperature, clock, timer
button to set
V.1

Publicidad

loading

Este manual también es adecuado para:

Manantial 190