Then the convector will go into "Heating" mode. The "Delayed start"
EN
mode can be set within a range from 01 to 96 hours.
Switching off "Heating" mode
You can exit "Heating" mode by pressing the "On/Off" button. Then the heater
will be switched off, and if it has been on by then, the red LED will go out. The
display will continue showing the room temperature.
"Anti-frost function"
If the room temperature falls below 5 degrees Celsius and the convector is off
(the red LED is not lit, but the mechanical switch is in position "I" (On)
heater will be automatically switched on in order to prevent from freezing.
Note: Entering a temperature correction for the temperature sensor does not
apply to this function.
Enabling and disabling the anti-frost function:
this function is enabled by default
to disable this function, the convector must be in "Off" mode, when
you press the
and "On/Off" button for three seconds the display will
show a blinking "ON", and by pressing the
"OFF" position, then you need to wait for 3 seconds and the function will
automatically go in "OFF" mode.
to enable this function again, the convector must be in "Off" mode, when
you press the
and "On/Off" button for three seconds the display will
show a blinking "OFF", and by pressing the
"ON" position, then you need to wait for 3 seconds and the function will
automatically go in "ON" mode.
"Temperature correction for the sensor" function
Due to the specifics of the temperature profile in some premises there may be
difference from the temperature shown on the display and the actually measured
temperature in the various locations of the heating appliance in the room.
See the temperature shown on the display of the appliance
Measure the temperature at a place where the temperature is
"comfortable" enough for you (usually at a height of 60 cm from the floor,
in sitting positon). If you find a difference within a range of ±4°С, you
can set the necessary correction in the convector's menu (It is important
to note that this function can be set only after the temperature has
become the same all around the room, and depending on the room
type, the minimum required time is 7 hours) by entering the temperature
difference resulting between the value on the display and the actually
measured temperature.
Note: This function is used with the purpose of providing better
temperature comfort and energy saving for the user of the electric
convector in the room which it is in. A temperature difference greater than ±4 °C
from the measured temperature in a specific location in the room indicates that
the room where you use the convector in is not well insulated or the temperature
is not the same all around the room.
Example: a convector in a room on a stone floor – the convector displays 18°С
(the set temperature is 22°С), the actually measured temperature (feeling of
reached comfort temperature) is 22°С at a height of 60 cm from the floor - > in
this case the convector continues to overheat the room (this is a direct energy
loss, but the convector cannot reach the set temperature because it measures the
temperature at a low height close to the floor) and it will never switch off. In this
case a temperature correction of +4°С needs to be applied to the sensor, thus the
convector will display 22°С and it will start switching off, and eventually it will
maintain the set temperature of 22°С).
The normal status of the function is 0°C by default
to change this value, the convector must be in "Off" mode, when you press
the
and "On/Off" buttons for three seconds the display will show a
blinking "0oc". You can press either the
to „4oc" range, then you need to wait for 3 seconds and the function will
be automatically stored.
to check what correction has been set, the convector must be in "Off"
mode, when you press the
will see the set temperature blinking on the display. By pressing the
buttons you can set a new value within a range from „-4oc" to „4oc".
Note: After activating the Return to Factory Settings function a new
temperature correction has to be entered, the value by default is 0°С)
Adaptive start
Adaptive start control is a function which predicts and initiates the optimal
start of heating up in order to reach the set temperature in the desired time.
this function is enabled by default
to change the value, the convector must be in "Off" mode, when you press
4
Operation and Storage Manual of Panel Heater
button you will reach the
button you will reach the
or
button to reach the „-4oc"
and "On/Off" buttons for three seconds you
the „ " and "Timer" buttons for three seconds the display will show a
blinking "A_On". You need to press the „ " button to reach „AOFF"; then you
need to wait for 3 seconds and the function will be automatically stored.
To return to „ON" status – the convector must be in "Off" mode; when you
press the
and "Timer" buttons for three seconds the display will show a
blinking "AOFF"; you need to press the
need to wait for 3 seconds and the function will be automatically stored.
This function can be set according to your needs. The appliance operates
for 17 hours following the set "comfort" temperature until it reaches a stable
), the
status – this is the reference comfort temperature. Also, a temperature lower
than the comfort one, with a difference from 4°C ± 1°С, has to be set for a
period of minimum 7 hours. When the adaptive operation is enabled, leave
the electronic thermoregulator of the appliance to operate for 4 cycles (4 х 24
hours) of comfort cycles (17 hours) and lowered temperature (7 hours). Upon
completion of the last period of low temperature, the comfort temperature
should be reached within ± 30 minutes deviation from the set time, with a
maximum difference of ± 1°C from the reference comfort temperature.
"Protection from children"
You can lock the buttons by continuously pressing the arrows
buttons simultaneously, in order to prevent any changes to the settings. When
this function is enabled you will see a lit green LED above the "padlock" icon.
Repeat the same action to unlock the buttons.
Note: If you press any of the buttons when the keypad is locked, the display
will show „LOC_"
"Open window"
The appliance is equipped with an integrated electronic device which
automatically switches off the heating power if a sharp decrease of
temperature is found in the room, when a window or a door is open. When the
temperature in the room begins increasing the heating will be automatically
restored. To activate this function you need to press the "Window" button;
a blinking green LED indicates that the function is enabled. Permanently lit
green LED indicates that the appliance is not heating up. To disable the "Open
window" function you need to press the "Window" button.
Note: When the "Open window" function is enabled, the "Anti-frost" function
does not work!
Settings in „Weekly programmer 24/7"
Note: Entering settings mode of "Weekly programmer" is possible only after
the time and the day of the week have already been set in the appliance.
To enter and exit the settings mode you need to continuously press the
"Timer" button.
There are three parameters to be set – day of the week, time and temperature;
switching among the three parameters is done by shortly pressing the "Timer"
button in the following sequence: day, time, temperature. To store the settings,
press shortly the "Timer" button after you finish the temperature setting.
You can change the value of each parameter by using the
Conditions for settings storing
a. After a point has been stored, it cannot be changed any more until you exit the
current setting.
b. Upon storing the first set point of a specific day in the current setting, all
previously set points of the day are cleared.
c. Storing further points of a specific day is possible only for the hours remaining
until the end of the day, after the last stored point.
d. When you have stored a point in the last hour of the day – 23.5h, you cannot
store any more points for this day in the current setting, and the display will
show "FUL" and the number of the day.
e. If nothing is stored in the current setting for a specific day, it will keep the
existing stored points up to the current setting.
The purpose of the settings is to store the three parameters in the so called
"SET POINTS", where the temperature set for each set point is implemented
until the next one is reached.
Example: If you have stored the temperature to be 22°C at 7 h and you wish the
or
temperature to remain the same until 19 h (you plan the temperature to increase
to 23°C then), you do not need store every single hour until 19 h, and you only
need to store the temperature to be 23°C at 19 h. By default the temperature will
be 22°C during this period of time (7 – 19 h).
The procedure for storing each point is as follows:
Upon entering settings mode the display will show dAY1, with the numeral
blinking to indicate that this is the parameter to be set (in this case it is the day
of the week).
a. to select the desired day, use the
button to reach „A_On", then you
and "Timer"
and
buttons.
and
buttons

Publicidad