After confirming the rotation direction, the motor automatically recognises the limit
switches.
The rolling shutter must be equipped with:
A - security locks or stiff fixing springs
B - fixed or removable stoppers for end slats.
It is very important to check the sturdiness of the rolling shutter.
From the remote control:
Use the remote control buttons A (up) or C (down) to control the motor and B (stop) to
stop it.
From the wired control:
During the first operational cycles, the motor will automatically learn the courses and the
wired control will operate in "dead man" mode.
The motor will run as long as the UP (raise) or DOWN (lower) button is held down,
stopping when the button is released.
Afterwards, just a quick press of the UP or DOWN button is enough to run the motor.
RESET OF THE ORIGINAL CONFIGURATION
Tn: Already programmed remote control
+
B
C
Tn
After the reset of the original configuration another confirmation of motor rotation
direction will be needed (see CONFIRMATION OF THE MOTOR DIRECTION Page 25).
INSTRUCTION FOR USE
A
+
B
C
Tn
26
B
+
B
C
Tn (4 sec)