AIR FILTER
The dehumidifiers are equipped with a 3-layer filter package to clean the circulated room
air. The 3-layer filter package consists of a screen filter and (separately packed) 3M™ HAF
and active carbon filter. These filters must be placed according to the instructions before
operating the dehumidifiers.
1 Screen filter; to remove bigger dust particles.
2 3M™ HAF filter; to remove unhealthy particles from the air such as pollen, bacteria,
animal dander and dust.
3 Active carbon filter sheet; to remove odours.
TO CLEAN, INSPECT OR EXCHANGE THE FILTERS:
TAKING OUT THE FILTERS:
•
Take out the water container (see chapter 'DRAINAGE OPTION').
•
Take out the screen filter by firmly pressing down the top of the screen filter with 2
or 3 fingers. The screen filter will bend and the two securing hooks at the top side of
the screen filter will be releasable from its dedicated holes. The screen filter is now
disconnected and can be easily removed.
•
Take out the now visible 3M
The screen filter has to be cleaned regularly with a vacuum cleaner to avoid blocking of
the air flow. It does not need periodically replacement.
New filter
The active carbon sheet can be cleaned with a vacuum cleaner when dusty but has to be
changed at the same time as the 3M™ HAF filter.
4
66
66
TM
HAF filter and the active carbon filter
Recommended change of filter