TROUBLESHOOTING
TROUBLE!
WHAT'S WRONG?
Spraying too much material.
Spraying too slowly.
MATERIAL RUNS
OR DRIPS
Spraying too close.
Viscosity too thin.
Nozzle loose
Nozzle breaks
MATERIAL DRIPS
FROM NOZZLE
Y-type seal ring of nozzle breaks
Material accumulated /cIog inside nozzle
Sprayer too far from surface.
TOO MUCH OVER
SPRAY
Too much material being sprayed.
Spray nozzle/tip clogged.
Y-type seal ring of nozzle missing
Pickup tube loose or clogged.
Canister loose
LITTLE OR NO
Quick refill lid loose
MATERIAL BEING
RELEASED
Spray gun unit not fully attached to the power unit
Flow control knob setting too low
Air inlet blocked
Material too thick.
MATERIAL BEING
SPRAYED IS
Viscosity of material is too high.
SPLATTERING
Viscosity of material too high.
Flow control knob setting too high
ATOMIZATION I9
Material accumulated /cIog inside nozzle
TOO COARSE
Air inlet blocked
Canister loose
Quick refill lid loose
Air filter clogged
Material in canister almost empty.
SPRAYER
PULSATES
Canister loose
Quick refill lid loose
Flow control knob setting too low.
SPRAY MATERIAL
Clearance to target area too large
DOES NOT COVER
Too few spray paths sprayed over target area
PROPERLY
Viscosity of material too high.
WHAT TO DO...
Reduce paint flow by turning material adjustment knob.
Increase speed of application.
Increase distance from surface.
Check dilution recommendation.
Screw nozzle tight
Change
Change
Clean
Reduce distance to surface.
Reduce paint flow by turning flow control knob
Clean nozzles.
Add seal ring to nozzle and assemble in place
Check tube.
Screw canister tightly in place
Screw quick refill lid tight in place
Check attachment of spray gun unit
Increase flow control setting
Clean or change air filter
Thin material per manufacturer recommendation.
Thin material per manufacturer recommendation.
Thin material per manufacturer recommendation.
Decrease flow control setting
Clean
Clean or change air filter
Screw canister tightly in place
Screw quick refill lid tight in place
Clean or change air filter
Refill canister.
Screw canister tightly in place
Screw quick refill lid tight in place
Increase flow control setting
Reduce spray distance
Apply more spray paths sprayed over target area
Thin material per manufacturer recommendation.