Gas pressure regulator/hose assembly
B.
20 lb propane tank
5.
Using your hand, turn the gas pressure regulator/hose
assembly clockwise to connect to the 20 lb propane tank
as shown.
Hand tighten only. Use of a wrench could damage the
quick coupling nut.
A.
Gas pressure regulator/hose assembly
B.
20 lb propane tank
Make sure that the cylinder valve connection device
properly mates with the connection device attached to the
inlet of the pressure regulator.
6.
Open the tank valve fully by turning the valve
counterclockwise. Wait a few minutes for gas to move
through the gas line.
7.
Before lighting the side burner, test all connections by
brushing on an approved noncorrosive leak-detection
solution. Bubbles will show a leak.
8.
If a leak is found, turn the tank valve off and do not use the
side burner. Contact a qualified gas technician to make
repairs.
To Disconnect the 20 lb PropaneTank:
1.
2.
B
3.
4.
11
Check that the burner control knobs are in the "OFF"
position and the side burner is cool.
Check that the 20 lb propane tank is in the "OFF" position.
If not, turn the valve clockwise until it stops.
Using your hand, turn the gas pressure regulator/hose
assembly counterclockwise to disconnect to the 20 lb LP
gas fuel tank as shown.
Hand loosen only. Use of a wrench could damage the
quick coupling nut.
A.
Gas pressure regulator/hose assembly
B.
20 lb propane tank
Place dust cap on cylinder valve outlet whenever the
cylinder is not in use. Only install the type of dust cap on
the valve outlet that is provided with the cylinder valve.
Other types of caps or plugs may result in leakage of
propane.