-After switching the appliance on, press
4
flash together;> Press
button to switch hour/minute setting, press the
>Press
button again to confirm and exit.
After switching the appliance on, press and hold
on icon and hour icon "88:" will flash together;>- Press the
to minute setting, minute icon ":88" will flash, press the
save and exit the timer setting interface.
Press
button to cancel the timer, while the "timer settings" mode is active
Press this
button to enter temp and EXV open step checking.
5
-Press the
and
buttons to check the temp sensor values and EXV open steps (parameters A-F).
-In any status, press this button
-Press the
and
buttons to check the system parameters.
NOTE:
1)
The timer 'ON' and timer 'OFF' functions can be set at the same time.
2)
The timer settings are repeating.
3)
The timer settings are still valid after a sudden power cut.
When connecting the appliance to the main power supply, all icons are
displayed on the controller screen for 3 seconds. After that an initial check
is undergoing.If everything is ok, the unit enters into a standby mode
SET TEMP
The heat pump will start working continuously in order to reach the set temperature. If the set temperature is adjusted to above
65oC, E-Heater will start working to continue heating the water to the set temperature.
If the outside air temperature is less than -10oC or above 44oC, theE-Heater will work only!
While the heat pump is working at a low outside air temperature, defrosting mode could be activated automatically in order to melt
the ice collected on the evaporator. This is a normal situation.
The maximum achievable water temperature by heat pump only, depends on outside air inlet temperature and could be seen on
picture (fig. 04)
If the set temperature (via control display) is more than achievable one as per picture, the E-heater will be switch ON automatically
to reach it.
In order to save energy, avoid setting the temperature above 55oC if not necessary! This way the heat pump
will work without the help of the E-Heater!
If the E-heater button
on the control panel has been turned on manually when the unit is instandby mode, the E-heater will work
only, until the temperature of the upper tank (5) reaches the set temperature TS2;
While the heat pump is running, press this button
heater will work according to the control program together with the compressor until theset temperature is reached.
The E-heater will start each week at the setting time automatically, regardless if the machine is on or in standby mode. E-heater will
stop working, when the tank temperature reaches 70oC (disinfection against legionella bacteria)
button to entry the clock setting interface, hour and minute icons "88:88"
button for 5 seconds to enter the timer setting interface, the timer
and hold for 5 seconds, entry the system parameter checking interface.
HEATING MODE
HEATING MODE
WATER TEMP
C
C
Fig. 03
"E heater only"
URGENT NEED OF HOT WATER!
to turn 'ON' "Boost mode". The heater icon
WITH CARE FOR YOUR HEALTH!
and
buttons to set the exact hour(s) and minute(s);
and
buttons to set the exact hour(s).>- Press
and
buttons to set the exact minute(s).>- Press button
4
button to transfer
again to
Fig. 04
will be shown, and the electrical