Descargar Imprimir esta página

Ferroli SUN G20 1S Instrucciones De Uso, Instalación Y Mantenimiento página 22

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

SUN G20 1S
Securing the burner to the boiler
Burner flange
fig. 2a
Assembly sequence
1)
Drill the plate closing off the
combustion chamber, observing the
dimensions given in Fig. 2a.
2)
Separate the flange/nosepiece "A"
from the burner body by unscrewing
the nut "B".
3)
Secure the flange/nosepiece "A" to
the boiler body with the screws "C".
4)
Take off the burner casing "D" by
unscrewing the two screws "E".
5)
Unscrew the couplings "L" and take
out the copper pipes "M".
6)
Slightly unscrew the two screws "F",
turn and extract the combustion
head "G".
7)
Insert the burner body onto the pin
"H" and secure it onto the flange
with the screw "B".
8)
Fit the combustion head back on
after checking that the nozzles are
suited to the power of the boiler.
9)
Connect the oil hoses to the pump.
10)
Check the settings.
11)
Fit the casing "D" back on and
secure it with the screws "E".
22
Cod. 3540G302 - Rev. 01 - 02/2015
fig. 2b
EN

Publicidad

loading