SUN G20 1S
Fitting nozzles
After determining the right nozzle to use, go ahead and fit them as follows:
1 Unscrew the screws "A"
2 Take off the casing "B"
3 Using a wrench, unscrew the coupling "C" by half a turn
4 Take the copper tube "D" out of the coupling
5 Slightly unscrew the screws "E"
6 Turn and take out the head/nozzle-holder assembly "F"
7 Unscrew the two screws "G"
8 Using a wrench, unscrew the nozzle "I"
26
fig. 5
Cod. 3540G302 - Rev. 01 - 02/2015
EN