16. UNIT OF WEIGHING (KG AND LB)
kg or lb is selectable. The unit of weighing is kg normally. You can change it to lb by pressing and holding
17. CONNECTION TO MINI-PRINTERS
Connect serial port printer type UP-16TS as follows:
Indicator
9 pin hole
Note: Before connection to printer, communication address is set as Adr=1; baud rate is set as b=9600.
Print operation with serial port printer is as follows:
17.1 Print: at weighing status, weighing data >20d and display is stable, press
can be operated only when the weighing data is back to <20d.
17.2 Accumulated print: at weighing status, press
17.3 Set to be automatic accumulation status, i.e. automatic print.
At weighing status, weighing data >20d and display is stable, weighing sheet is printed out. The second printing can be operated only when
the weighing data is back to <20d and more weight is loaded.
Attached with print sample:
NORMAL PRINTING
No:1 (serial number)
Gross: 3940 kg (gross weight)
Tare: 2000 kg (tare weight)
Net: 1940 kg (net weight)
18. PRECAUTION
Indicator should be far away from heat resource while using.
Do not place the indicator in the dusty surroundings or the site vibrant.
Cannot use full capacity. Over load stops hitting platform support is not permitted.
To ensure to keep out of chemical erosion, Operating temperature range will be -10...50ºC,relative humidity is no less than 85%,without
any corrupt gas in air.
Never pour the water into the indicator.
Housing, head pallet, wire connector should be sealed entirely. Users do not open sealed device or connect with wire without any expert
advice. In case any malfunction of indicator occurs, please sent the indicator for maintenance.
The indicator will charge the internal battery at all times when it is connected to the main power
3
TXT
2
5
GND
7
, then press
ACCUMULATION PRINTING
No:9 (serial number)
W: 8225 kg (accumulated weight)
USER'S MANUAL BR80-BR90
serial Port printer
25 pin needle
weighing sheet is printed out. The second printing
, accumulated printing can be operated.