PREPARATION
Before beginning assembly of product, make sure all parts are present. Compare parts with package contents list and hardware
contents. If any part is missing or damaged, do not attempt to assemble, install or operate the product. Contact customer service for
replacement parts at 1-877-319-3757, 7:30 a.m. - 4:30 p.m., CST, Monday - Friday.
Tools Required for Assembly (not included): Hammer, Flathead Screwdriver, Wire Connectors, Nails, Duct Tape, Phillips Screwdriver,
and Utility Knife or Drywall Saw.
Helpful Tools (not included): Electric Drill, Drill Bits
WARNING: RISK OF ELECTRIC SHOCK. Ensure the electricity to the wires you are working on is shut off. Either remove the
fuse or turn off the circuit breaker before removing the existing bath fan or installing the new one
Before removing your current ventilation fan, verify the wall switch box has the required wires necessary for this installation.
These supply wires are power (black) and neutral (white), as shown in the wiring diagram below. If you do not see both of
these wires, consult a licensed electrician.
Check area above installation location to be sure that wiring can run to the planned location and that duct work can be run and the area
is sufficient for proper ventilation.
Inspect duct work and wiring before proceeding with installation.
Before installation, provide inspection and future maintenance access at a location that will not interfere with installation work.
You may need the help of a second person to install this fan; one person on the attic side and one on the room side.
Note: Installation may vary depending on how the previous bath fan was installed. Supplies necessary for the installation of your bath fan
are not all included; however, most are available at your local home improvement or hardware store.
DIMENSION REQUIREMENTS
Ceiling
Opening (L)
Opening (W)
10-13/16 in.
WIRING
All wiring must be connected for full functionality. Do not use metal wall plate with switch.
Automatic Terminal Switch
Capacitor For
Long Life
of Motor
Motor
Fan Housing
House
Wires
HomewerksWW.com
Ceiling
Ceiling
Opening (H)
10-1/2 in.
8-1/2 in.
Humidity
Sensor
Electrical
Box
Quick Connector
Product Wires
Housing
Dimension (L)
10-1/4 in.
Black Wire
To Switch
White Wire
To Neutral
Green Wire
To Ground
• Strip wires 3/8 in. - 1/2 in.
• Grip the wire firmly and push the stripped end of the
wire into the open port of the connector. Use only one
conductor per port.
• Verify the stripped end of the wires is fully inserted to
the back of the connector.
5
.
Housing
Dimension (W)
10-1/4 in.
WARNING: Wiring must comply with all
applicable electrical codes. Turn off power
before removing or installing connectors.
WARNING: COPPER TO COPPER ONLY.
Do not use aluminum wire.
CAUTION: Accessory part (quick connector)
should meet installation instructions below.
NOTE: The connector is reusable on solid
wires of the same wire gauge or smaller. Do
not reuse the connector on stranded wires.
CAUTION: Wiring maximum temperature rating
221˚F (105˚C). 600V maximum for building wiring
and 1,000V maximum for signs and light fixtures.
The acceptable wire range is 18-16 AWG Sol. Cu.
Housing
Dimension (H)
8 in.