Descargar Imprimir esta página

Reset The Unit; Modelling Lamp Features & Setup - Elinchrom BRX 250 Manual De Funcionamiento

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 65
Programmable features - Reset
How to „Reset" the BRX
In case you need to „RESET" the BRX to the manufacturer settings please follow the steps below:
1.
Switch the unit "off"
2.
Press both flash power up / down buttons (10) at the same time and switch the unit on
3.
The Digital LED multi display (6) flashes in fast mode
4.
Do not continue to press the touches, the resetting procedure is completed
Modelling lamp features & setup
Modelling lamps and fuses for 110 V & 230 V
Unit
Modelling lamp 110V
BRX 250
100W krypton / 23006
BRX 500
100W krypton / 23006
Modelling lamp modes
> Setting:
• Press "Free/Prop" button to set Modelling lamp ON to proportional mode or OFF
• Press "Modelling" up or down button to set Modelling lamp to free mode, press
"Free/Prop" to switch Modelling lamp OFF.
• Prop-LED is ON: proportional Modelling lamp setting.
> LED Indication:
• Free-LED is ON: free Modelling lamp setting.
• Prop and Free-LED's are OFF: Modelling lamp is inactive.
Setup Visual-Flash-Control (VFC) mode
> Enter VFC setup :
1. Press "Free/Prop" push button for more than 2 seconds, until the display shows "F.X" ("X" is 0 or
1) to enter into the Modelling lamp setup menu.
.
2
Use the "Flash-Power" up and down button to change setting:
- "F.0": Visual-Flash-Control = OFF. Modelling lamp remains ON after flash.
- "F.1": Visual-Flash-Control = ON. Modelling lamp switches off during recharging.
3. The display switches back to normal mode after approx. 4 seconds if no button is pressed. The
settings are automatically stored.
4. Standard setting is "F.0", VFC = OFF
Proportional modelling lamp setup (PMS)
(When using heads of different maximum power)
>
Enter PMS setup:
1. Press "Free/Prop" button for more than 2 seconds to enter into the Modelling lamp setup menu.
The display shows "F.X", then press the "Free/Prop" button once more to the PMS menu, the
display shows "-.X"
2. Use the "Flash-Power" up and down button to change the settings:
• "-.0": PMS = OFF, Modelling lamp is set to maximum.
• "-.1": PMS = -1 f-Stop, Modelling lamp is reduced by 1 f-stop.
Modelling lamp 230V
100W krypton / 23002
100W krypton / 23002
English
Socket
Fuse
E27
2.5AF / 19033
E27
2.5AF / 19033
9