Waeco AirCon Service Center ASC 1300 G Instrucciones De Uso página 116

Estación de mantenimiento de aire acondicionado
Ocultar thumbs Ver también para AirCon Service Center ASC 1300 G:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Operation
24. Deselect "Rec/Recycling phase" using No (the setting flashes) and
press ENTER to confirm.
25. Select "Vacuum phase" (the setting flashes) and press ENTER to
confirm.
26. Select "Filling phase" (the setting flashes) and press ENTER to
confirm.
27. Enter the refrigerant filling quantity (note the oil filling quantity of the
compressor).
28. Then follow the instructions on the display (6):
Select the setting (which then flashes) and press ENTER to confirm.
29. Select "Process start" by pressing ENTER.
✓ After filling is complete, you will be prompted to disconnect the hoses
of the AirCon Service Center from the vehicle air conditioning system.
30. Disconnect the service hoses (10) and (11) and press ENTER to
confirm.
The service hoses are then emptied. The device is then ready for
further use.
31. Put the valve caps of the vehicle air conditioning system back on the
connections.
116
AirCon Service Center
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido