WIRING
Note: This range hood must be properly
grounded. The unit should be installed by a
qualified electrician in accordance with all
applicable national and local electrical codes.
1. Remove the wiring box cover. Remove a
knockout from the wiring box.
2. Secure the conduit to the wiring box
through a conduit connector.
3. Make electrical connections. Connect white
to white, black to black and green to green.
4. Replace wiring box cover and screws. Make
sure that wires are not pinched between
cover and box.
CONNECT DUCTWORK
Ducted Configuration
1. Use screws (4.8x38mm) and wall anchors
to secure upper bracket to the ceiling or
wall as shown.
2. Use 6" round metal duct to connect the duct
collar on the hood to the ductwork above.
3. Use duct tape to make all joints secure and
air tight.
4. Remove the 2 screws securing the flues.
5. Carefully place the lower decorative flue
into the recessed area of the range hood
top.
6. Extend the upper flue to the ceiling and
secure with two mounting screws
(3.9x9.5mm).
7. Secure lower flue to hood with the two
mounting screws provided (3.9x9.5mm).
FASTEN
FLUE TO
HOOD & UPPER
BRACKET WITH
SCREWS
(3.9x9.5mm)
WIRING BOX
COVER
DUCT
COLLAR
UPPER
BRACKET
- 7 -
FASTEN
UPPER
BRACKET
TO CEILING &
WALL WITH
SCREWS
(4.8x38mm)
DECORATIVE
FLUE
DUCT TAPE
AIR VENT
POSITION FOR
DUCTED
CONFIGURATION
6" ROUND
METAL DUCT