Descargar Imprimir esta página

Mitsubishi Electric MSZ-HR35VF Manual De Instrucciones página 8

Ocultar thumbs Ver también para MSZ-HR35VF:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
● OPERATING INSTRUCTIONS ●
W
i-Fi INTERFACE SETTING UP (VFK type only)
This Wi-Fi interface, communicates the status information and controls the commands from the MELCloud by connecting to the indoor unit.
Front panel
Wi-Fi interface
S
PECIFICATIONS
EN
Indoor
Model
Outdoor
Function
Power supply
Capacity
Input
Indoor
Weight
Outdoor
Refrigerant fi lling capacity (R32)
Indoor
IP code
Outdoor
LP ps
Permissible excessive
operating pressure
HP ps
Indoor (Super High/
High/Med./Low)
Noise level (SPL)
Outdoor
Guaranteed operating range
Upper limit
Cooling
Lower limit
Upper limit
Heating
Lower limit
Wi-Fi interface
Model
Input Voltage
Power consumption
Size H×W×D (mm)
Weight (g)
Transmitter power level (MAX.)
RF channel
Radio protocol
Encryption
Authentication
Software Version
For Declaration of Conformity, please go to the website below.
http://www.mitsubishielectric.com/ldg/ibim/
EN-6
Note:
• Set up a connection between the Wi-Fi interface and the Router. Refer to the SETUP MANUAL and SETUP
QUICK REFERENCE GUIDE provided with the unit.
• For SETUP MANUAL, please go to the website below.
https://www.melcloud.com/Support
• For MELCloud User Manual, please go to the website below.
https://www.melcloud.com/Support
MSZ-HR25VF(K)
MUZ-HR25VF
Cooling
kW
2.5
kW
0.80
kg
kg
23
kg
0.40
MPa
MPa
dB(A)
43/37/30/21 43/37/30/21 46/38/31/22 44/37/30/21 44/39/34/24 46/40/32/24 45/40/36/28 47/41/34/27
dB(A)
50
*1 Refer to the spec name plate for the unit weight.
Indoor
Outdoor
32°C DB
46°C DB
23°C WB
21°C DB
-10°C DB
15°C WB
27°C DB
24°C DB
18°C WB
20°C DB
-10°C DB
-11°C WB
MAC-577IF2-E
DC12.7 V (from indoor unit)
MAX. 2 W
73.5×41.5×18.5
46 (including cable)
20 dBm @IEEE 802.11b
1ch ~ 13ch (2412~2472 MHz)
IEEE 802.11b/g/n (20)
AES
WPA2-PSK
XX.00
MSZ-HR35VF(K)
MUZ-HR35VF
Heating
Cooling
Heating
~ /N, 230 V, 50 Hz
3.15
3.4
3.6
0.85
1.21
0.975
8.5
22 or 23 or 24 *1
0.45
IP 20
IP 24
2.77
4.17
50
51
51
Note:
Rating condition
Cooling — Indoor:
Heating — Indoor:
DB: Dry Bulb
WB: Wet Bulb
W
HEN YOU THINK THAT
TROUBLE HAS OCCURRED
In the following cases, stop using the air conditioner and consult your dealer.
• When water leaks or drips from the indoor unit.
• When the operation indicator lamp blinks.
• When the breaker trips frequently.
• The remote control signal is not received in a room where an electronic ON/
OFF type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.
• Operation of the air conditioner interferes with radio or TV reception. An ampli-
fi er may be required for the affected device.
• When an abnormal sound is heard.
• When any refrigerant leakage is found.
MSZ-HR42VF(K)
MSZ-HR50VF(K)
MUZ-HR42VF
MUZ-HR50VF
Cooling
Heating
Cooling
4.2
4.7
5.0
1.34
1.30
2.05
9
32.5 or 34 *1
34 or 35 *1
0.70
0.80
50
51
50
27°C DB, 19°C WB
Outdoor: 35°C DB
20°C DB
Outdoor: 7°C DB, 6°C WB
Heating
5.4
1.55
51

Publicidad

loading