Creating Multiple Or Group Controls; Group Control; Tips And Recommendations; Problems With The Heating Mod/Var Ramp Rts-Hr1 - SOMFY Ramp RTS-HR1 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
Installation guide
2)
Briefly press the PROG button on the RTS control point (b) to be
added or removed:
-
The heating lamp comes on then goes out; the RTS control point
has been added/removed.

7.3 Creating multiple or group controls

7.3.1 Group control

Group control: an RTS control point controls several Heating Mod/Var
Ramp RTS-HR1s.
1)
Switch off the power supply to the Heating Mod/Var Ramp RTS-HR1
(c, d and e) to be controlled by a single RTS control point.
2)
Switch on the power supply to the first Heating Mod/Var Ramp
RTS-HR1 (e) to be linked to the RTS control point.
3)
Simultaneously press the Up/Down buttons on the RTS control point:
the heating lamp comes on then goes out.
4)
Press the PROG button on the RTS control point: the heating lamp
will come on then go out again to indicate that the RTS control point
has been programmed into the Heating Mod/Var Ramp RTS-HR1.
5)
Switch off the power supply to the newly linked Heating Mod/Var
Ramp RTS-HR1 (c) before adding the next Heating Mod/Var Ramp
RTS-HR1.
6)
Switch on the power supply to another Heating Mod/Var Ramp
RTS-HR1 to be linked and repeat steps 3), 4) and 5) for each Heating
Mod/Var Ramp RTS-HR1 (d, e, etc.).
7)
Switch on the power supply to all the Heating Mod/Var Ramp RTS-HR1s linked to
control point.
7.3.2 Multiple control
Multiple control: a Heating Mod/Var Ramp RTS-HR1 is controlled by several RTS control points.
Caution! A maximum of 12 control points may be programmed into a Heating Mod/Var Ramp
RTS-HR1.
1)
Press the PROG button on the programmed RTS control point (a)
until the heating lamp comes on then goes out: the Heating Mod/Var
Ramp RTS-HR1 will be in its programming mode for 2 minutes.
2)
Briefly press the PROG button on the RTS control point (b) to be
added:
-
The heating lamp comes on then goes out; the RTS control point
has been added/removed.
-
Repeat these two steps to add each RTS control point.

8. Tips and recommendations

8.1 Problems with the Heating Mod/Var Ramp RTS-HR1?

Problems
The
Heating
Mod/Var
Ramp RTS-HR1 cannot be
operated by pressing one
of the buttons on the RTS
control point.
The Heating Mod/Var Ramp
RTS-HR1 does not heat up
sufficiently.
Copyright © 2008-2010 Somfy SAS. All rights reserved.
Possible causes
The power supply is faulty.
The
RTS
control
point
has
programmed into the Heating Mod/Var Ramp
RTS-HR1 .
The RTS control point used is not compatible
with the Heating Mod/Var Ramp RTS-HR1.
The batteries in the RTS control point are
weak.
The correct distance and height of the
installation have not been respected.
Heating Mod/Var Ramp RTS-HR1
Check the power supply.
not
been
Follow the procedure for programming an RTS control
point.
Ensure the two products are compatible.
Replace the batteries with identical ones.
Check the distance and height of the installation.
+
1
2
a
b
PROG.
PROG.
2 min.
1
c
OFF
d
e
2
3
c
ON
c
4
c
c
PROG.
the RTS
+
1
2
a
b
PROG.
PROG.
2 min.
Solutions
39

Publicidad

Tabla de contenido
loading

Tabla de contenido