Replacing A Lost Or Broken Control Point; Restoring The Original Configuration; Technical Data - SOMFY Ramp RTS-HR1 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
Heating Mod/Var Ramp RTS-HR1
Problems
The Heating Mod/Var Ramp
RTS-HR1 does not heat up
suffi ciently. (next)
The Heating Mod/Var Ramp
RTS-HR1 does not switch
on.

8.2 Replacing a lost or broken control point

Caution: This reset is carried out if all the RTS control points have been lost or broken.
Caution! This reset removes all control points but retains the favourite heat level programmed.
Caution! Only switch off the power to the Heating Mod/Var Ramp RTS-HR1 to be reset!
CAUTION! Do not use an Inis RT/Inis RTS control point for resetting
1)
Cut the power supply for 2 seconds.
2)
Switch the power supply back on for approximately 10 seconds (for
at least 5 seconds but no longer than 15 seconds).
3)
Cut the power supply for 2 seconds.
4)
Switch the power supply back on: the heating lamp fl ashes slowly.
5)
Briefl y press the PROG button on the new RTS control point (f):
-
The heating lamp will come on then go out again to indicate that
the new RTS control point has been programmed into the Heating
Mod/Var Ramp RTS-HR1.
8.3 Restoring the original confi guration
Caution! This reset removes all control points and resets the favourite heating level to 33% of the
total power.
Caution! Only switch off the power to the Heating Mod/Var Ramp
RTS-HR1 to be reset!
Caution! Do not use the Inis RT/Inis RTS control point for resetting!
1)
Cut the power supply for 2 seconds.
2)
Switch the power supply back on for approximately 10 seconds (for
at least 5 seconds but no longer than 15 seconds).
3)
Cut the power supply for 2 seconds.
4)
Switch the power supply back on: the heating lamp fl ashes slowly.
5)
Press the PROG button on the RTS control point until the heating
lamp comes on then goes out twice in succession: all control points
have been removed.
-
Follow the procedures in the section entitled "Commissioning" to
add RTS control points.

9. Technical data

Radio frequency
Power supply
Maximum total power
Index protection rating
Operating temperature
Safety level
40
Possible causes
The capacity of the Heating Mod/Var Ramp
RTS-HR1 is not suffi cient.
The correct fuse has not been fi tted to the
equipment.
One or more heating lamps is blown or
broken.
The heating lamp(s) linked to the Heating Mod/
Var Ramp RTS-HR1 exceed 2000 W.
433.42 MHz
230 V ~ 50 Hz
2000 W
IP24
- 20°C to + 60°C
Class I
See the heated surface in the technical data.
Check the rating of the fuse. To operate the ramp
correctly, a 16 A delay fuse is required.
Replace the heating lamp(s).
Ensure that the heating lamp(s) linked to the Heating
Mod/Var Ramp RTS-HR1 do not exceed 2000 W in
total.
1
3
5
PROG.
1
3
5
PROG.
Number of programmable RTS
control points
Dimensions (mm)
Weight (kg)
Heating lamp
Service life (hours)
Heating surface (m2)
Copyright © 2008-2010 Somfy SAS. All rights reserved.
Installation guide
Solutions
OFF
ON
2
2 sec.
10 sec.
OFF
ON
4
...
2 sec.
a
f
OFF
ON
2
2 sec.
10 sec.
OFF
ON
4
...
2 sec.
12 maximum
483 x 176 x 230
3.5
Philips® HeLeN
5000
16

Publicidad

Tabla de contenido
loading

Tabla de contenido