FAULTS
ERROR CODE
E1
E2
E3
E4
E5
ONLY FOR SALES WITHIN THE
EUROPEAN COMMUNITY (EU)
This appliance is marked according to the European Directive 2012/19 / EU (WEEE). The symbol on the
product indicates that this product should not be treated as household waste.
Ensure that this product is not entered as part of the flows of municipal waste but treated as
professional WEEE.
24
ERROR TYPE
Battery protection or temperature sensor malfunction shutdown
(The voltage is outside the cut-out setting).
Fan over-current cut-out
(The fan loads the electronic unit with more than 1Apeak).
Motor start error
(The rotor is blocked or the differential pressure in the refrigeration system is too high (>5
bar)).
Minimum motor speed error
(If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed
1,850 rpm).
Thermal cut-out of electronic unit
(If the refrigeration system has been too heavily loaded, or if the ambient temperature is high,
the electronic unit will run too hot).
TB 31-41-51 OFF_20230111