Tenth light
flashing
First and tenth
light flashing
All lights
flashing
SY-C20 CONTROLLER
When the fault code appears on the controller display, it indicates that the power wheelchair is in an abnormal
condition. The meaning of the display and the recommended method of elimination are shown in the following
table.
Indicator
Fault code
status
C1
Long blink
C2
Long blink
C3
Long blink
C4
Long blink
C5
Long blink
C5
Short blink
C5
Long blink
C6
Long blink
C7
Long blink
Motor overload
High battery voltage
The rocker is not in the
centre of the joystick.
Fault description and
Alarm sound
warning
Long time alarm
Communication failure
The joystick is not in
Long time alarm
the home position
Control conflict (If your
wheelchair has front
Long time alarm
controllers and rear
controllers)
The brake lever has not
Long time alarm
been set to the electric
state
Overload warning (First
Long time alarm
stage)
Short time
Overload warning
alarm
(Second stage)
Overload warning
Long time alarm
(Third stage)
Long time alarm
Ignition failure
Left and right-hand
Long time alarm
wheel overvoltage
warning
Release the control bar to resume.
Check the output voltage, it must not be higher than 35V.
1. Do not touch the rocker arm when it is switched on.
2. Turn off, shake the rocker, and try to bring it back to the
centre, if the problem persists, please contact after-sales
service.
Method of elimination
Check if the wiring harness is correctly installed
and connected
Switch off the power, release the joystick to the
centre position and then switch it on
Disconnect power to the front controllers and the
rear controllers, and select one to turn on
Check if the engine is in running condition
Reduce the load on the wheelchair or release the
joystick to the centre position, the wheelchair is
reset
Restart
The joystick returns to the centre position until
the overvoltage warning is removed