User and installation manual WE 30
6.
Door switch
The door switch refers to the switch on the sauna door. This switch complies with regulations. Public and private
saunas must have a door switch, i.e. saunas where the heater can be switched on from outside the sauna, e.g. using
an On/Off
button or a similar method.
The control panel automatically registers when the door switch is connected to the heater's OLEA 103 circuit board.
When using the sauna for the first time after the installation, close the door to the sauna room and turn on electricity
using the heater's main switch.
If the door is opened before the heating sequence is started, (pre-set heating) automatic use (remote use) is disabled
after one minute. The door must be closed and the function restarted from the control panel.
If the door has been left open for more than five minutes while the heater is on, the heater is automatically turned off.
The heater can be turned on again from the control panel after the door is closed. The fault indicator light, if installed,
will start flashing. See installation instructions below.
Door switch instructions for installation and connection
The door switch is installed outside the sauna room on the upper edge of the door, at least 300 mm from the inner
corner.
The switch part is installed on the door frame and the magnet is installed on the door. The distance between the
switch and the magnet is 18 mm.
When the door switch is installed on the top part of the door, Sauna360 recommends using the Sauna360 model with
product number 0043233, SSTL 8260371.
When the door switch is installed on the bottom part of the door, Sauna360 recommends using the Sauna360 model
with product number SP11000326, SSTL
See the installation and user instructions supplied with the heater for instructions.
Door switch
Min. 300 mm
Magnet on
the door
Door switch
position when
installed on
lower part of the
door
Figure 3. Installing the door switch
7.
Remote controlling
The contactor case can be controlled remotely by a closing contact, which can also be pulse triggered for on-off,
wire the contacts to pins 3 and 4 of a RJ10 connector. The cable size is 24 AWG or 26 AWG. The maximum length
of the 24 AWG cable is 200 m, while the 26 AWG cable must be no longer than 130 m.
Remote control switch (Ex switch)
Pin 1
Pin 2
Pin 3
From switch
Pin 4
Table 2. Instructions for connecting OLEA 103 RJ 10 circuit board for remote control
8263280.
Junction box
OLEA 103
Max 18 mm
Connection
box
Door switch
Magnet for the door
Pin 1
Pin 2
Pin 3
Pin 4
Table 1. Connecting the door switch to an RJ10 connector.
GND
To switch
12 VDC
WE 30
Figure 2. Pin layout of a RJ10 circuit
3
4
Connect the brown and
black door switch wires.
(closing contact)
Door switch
Door switch
GND
Door switch
12 VDC
6
board connector
Conductor colour
Orange
Green/white