Descargar Imprimir esta página

Bosch PLS Manual De Usuario página 18

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
Parking Lot Sensor | PLS
2.2 Installing the sensor base
The sensor base is attached to the substrate (e.g., concrete, asphalt). To do this, we recommend a two-component
adhesive. We have already had good experience with the following adhesive: DELO®-PUR 9692 (universal 2-
component polyurethane adhesive available in 50 ml and 200 ml cartridges). We will be happy to support you with
procurement. We recommend attaching several sensor bases first and only then installing the sensors.
Required material for installing the parking lot sensor
Figure 2
Material for attachment
1
Disposable gloves (protection against contact with adhesive)
2
Two-component adhesive
3
Adhesive press (these differ, depending on the cartridge size)
4
Mixing tip
5
Tape rule
6
Sensor base
7
Sensor core (sensor)
8
T20 screw
9
Sensor cap (sensor sealing cap)
Preparation of the parking space
The parking space must be free of dirt, dust, oil, water and other contaminants. For this purpose, at least one swept
area should be prepared. However, it is recommended to clean the surface to remove contamination using a high-
pressure cleaner and a burner. The installation must take place in the center of the parking space (intersection of the
two diagonals, see Fig. 3) in order to ensure optimum sensor accuracy.
Figure 3 Determination of the center of the parking space
4 | 14

Publicidad

loading