Safety and operating instructions
Stop the machine by releasing the trigger. The
trigger returns automatically to the stop position.
Operating
Starting a cut
Stand in a stable position with your feet well away
from the inserted tool.
Press the machine against the working surface
before you start.
Start collaring at such a distance from the edge
that the machine is capable of breaking the
material without levering.
Never try to break off too large pieces. Adjust the
breaking distance (A) so that the inserted tool
does not get stuck.
Breaking
Let the machine do the work; do not press too
hard.
Avoid working in extremely hard materials for
example granite and reinforcing iron (re-bar)
which would cause substantial vibrations.
Any form of idling, operating without insertion
tool or operating with an uplifted machine must
be avoided.
When the machine is lifted, the start and stop
device must not be activated.
Check regularly that the machine is well
lubricated.
16
www.CrowderSupply.com • Toll Free: 888-883-5144
CP 0122 S, CP 0122 SL, CP 0125 S
When taking a break
During all breaks you must place the machine in
such a way that there is no risk for it to be
unintentionally started. Make sure to place the
machine on the ground, so that it can not fall.
In the event of a longer break or when leaving the
workplace: Switch off the power supply and then
bleed the machine by activating the start and stop
device.
Maintenance
Regular maintenance is a basic requirement for the
continued safe and efficient use of the machine.
Follow the maintenance instructions carefully.
Before starting maintenance on the machine,
clean it in order to avoid exposure to hazard
substances. See "Dust and fume hazards"
Use only authorised parts. Any damage or
malfunction caused by the use of unauthorised
parts is not covered by warranty or product
liability.
When cleaning mechanical parts with solvent,
comply with appropriate health and safety
regulations and ensure there is satisfactory
ventilation.
For major service to the machine, contact your
nearest authorised workshop.
After each service, check that the machine's
vibration level is normal. If not, contact your
nearest authorised workshop.
Every day
Before undertaking any maintenance or changing
the insertion tool on pneumatic machines, always
switch off the air supply and bleed the machine by
depressing the start and stop device then disconnect
the air hose from the machine.
Clean and inspect the machine and its functions
each day before the work commences.
Check the tool retainer for wear and function.
Conduct a general inspection for leaks and
damage.
Check that the air inlet nipple is tightened and
that the claw coupling is free from damage.