LINE VOLTAGE
MODEL: VF LDB  L-EN
HIGH BTU/HR (kW):
LOW BTU/HR (kW):
MODEL: VF LDB  L-EP
HIGH BTU/HR (kW):
LOW BTU/HR (kW):
NG Models
Altitude
Input
Reduced Input
P4
Manifold Pressure: 3.5" w.c.(NG)
Minimum Supply Pressure: 5" w.c. (NG)
Maximum Supply Pressure: 7"* w.c. (NG)
Pression au Collecteur: .87wPA d'une colonne d'eau (GN)
Pression d'Alimentation Min.: 1.25wPA d'une colonne d'eau (GN)
Pression d'Alimentation Max.: 10.5wPA ** d'une colonne d'eau (GN) **
Maximum inlet pressure not to exceed 13".
Minimum clearance to combustible materials: Top, sides & back:
per standoff spacers for framing and finishing materials. For non-com-
bustible framing and finishing materials, see installation manual.
VENTED DECORATIVE GAS APPLIANCE: NOT A SOURCE OF HEAT; NOT FOR USE WITH SOLID FUEL.
APPAREIL DÉCORATIF À GAZ VENTILÉ: PAS UNE SOURCE DE CHALEUR; NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.
THIS APPLIANCE NEEDS FRESH AIR FOR SAFE OPERATION AND MUST BE INSTALLED
SO THERE ARE PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR.
CET APPAREIL A BESOIN D'AIR FRAIS POUR UN FONCTIONNEMENT SÉCURISÉ ET DOIT ÊTRE INSTALLÉ POUR IL Y A DES
DISPOSITIONS POUR UN AIR DE COMBUSTION ET DE VENTILATION ADÉQUAT.
This appliance is not for installation in manufactured homes. Cet appareil n'est pas destiné à être installé dans des maisons préfabriquées.
The installation, including provisions for combustion, ventilation air, and required minimum permanent vent opening,
must conform with National Fuel Gas Code (ANSI Z223.1/NFPA 54) and applicable local building codes.
L'installation, y compris les dispositions pour la combustion, l'air de ventilation et l'ouverture de ventilation permanente minimale requise,
doit être conforme au National Fuel Gas Code (ANSI Z223.1 / NFPA 54) et aux codes du bâtiment locaux applicables.
WARNING: This gas appliance must not be connected to a chimney fuel servicing a solid fuel burning appliance.
AVERTISSEMENT: Cet appareil à gaz ne doit pas être raccordé à un combustible
WARNING: THIS FIREPLACE IS NOT INTENDED FOR BURNING SOLID FUELS.
AVERTISSEMENT: CE FOYER N'EST PAS DESTINÉ À BRÛLER DES COMBUSTIBLES SOLIDES.
GRAND CANYON GAS LOGS • QUEMADOR BED ROCK II SIN VENTILACIÓN | 25
DO NOT REMOVE THIS LABEL
See installation & operating instructions for this model.
Contact local building officials about restrictions and
installation specifications in your area.
DATE
OF MFG.
24 
36 
16,000 (4.00kW)
32,000 (9.37kW)
10,000 (2.93kW)
20,000 (5.36kW)
24 
36 
16,000 (4.00kW)
32,000 (9.37kW)
10,000 (2.93kW)
20,000 (5.36kW)
MANIFOLD PRESSURE:
ELECTRICAL RATING: 120V/60HZ
GAS TYPE: NATURALGAS /LIQUID PROPANE
de cheminée desservant un appareil à combustible solide.
SERIAL
#
48 
39,500 (11.57kW)
27,000 (7.91kW)
48 
39,500 (11.57kW)
27,000 (7.91kW)
Pression au Collecteur: 2.40wPA d'une colonne d'eau (LP)
Pression d'Alimentation Min.: 2.74wPA d'une colonne d'eau (LP)
Pression d'Alimentation Max.: 3.49wPA * d'une colonne d'eau (LP)
** Pression d'alimentation maximale ne devait pas dépasser
3.49wPA. Dégagements minimaux des matériaux combustibles:
Dessus, côtés et arrière: selon les espaceurs de dégagements
pour les matériaux d'ossature selon le manuel du
propriétaire pour les matériaux de finition
TESTED &
REPORT NO.
LISTED BY:
ANSI-Z21.11.2.2016
Uncented Room Heater
ANSI-Z21 60-2017
CSA 2.26-2
Decorative gas appliances for
installation in solid-fuel
REPORT NO. #
burning fireplaces.
60 
39,500 (11.57kW)
27,000 (7.91kW)
60 
39,500 (11.57kW)
27,000 (7.91kW)
LP Models
Alimentation / Alimentation Réduite
Manifold Pressure: 10.5" w.c. (LP)
Minimum Supply Pressure: 11" w.c. (LP)
Max. Supply Pressure: 14"* w.c. (LP)
Élévation
P4