LINE VOLTAGE
MODEL: VF LDB L-EN
HIGH BTU/HR (kW):
LOW BTU/HR (kW):
MODEL: VF LDB L-EP
HIGH BTU/HR (kW):
LOW BTU/HR (kW):
NG Models
Altitude
Input
Reduced Input
P4
Manifold Pressure: 3.5" w.c.(NG)
Minimum Supply Pressure: 5" w.c. (NG)
Maximum Supply Pressure: 7"* w.c. (NG)
Pression au Collecteur: .87wPA d'une colonne d'eau (GN)
Pression d'Alimentation Min.: 1.25wPA d'une colonne d'eau (GN)
Pression d'Alimentation Max.: 10.5wPA ** d'une colonne d'eau (GN) **
Maximum inlet pressure not to exceed 13".
Minimum clearance to combustible materials: Top, sides & back:
per standoff spacers for framing and finishing materials. For non-com-
bustible framing and finishing materials, see installation manual.
VENTED DECORATIVE GAS APPLIANCE: NOT A SOURCE OF HEAT; NOT FOR USE WITH SOLID FUEL.
APPAREIL DÉCORATIF À GAZ VENTILÉ: PAS UNE SOURCE DE CHALEUR; NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.
THIS APPLIANCE NEEDS FRESH AIR FOR SAFE OPERATION AND MUST BE INSTALLED
SO THERE ARE PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR.
CET APPAREIL A BESOIN D'AIR FRAIS POUR UN FONCTIONNEMENT SÉCURISÉ ET DOIT ÊTRE INSTALLÉ POUR IL Y A DES
DISPOSITIONS POUR UN AIR DE COMBUSTION ET DE VENTILATION ADÉQUAT.
This appliance is not for installation in manufactured homes. Cet appareil n'est pas destiné à être installé dans des maisons préfabriquées.
The installation, including provisions for combustion, ventilation air, and required minimum permanent vent opening,
must conform with National Fuel Gas Code (ANSI Z223.1/NFPA 54) and applicable local building codes.
L'installation, y compris les dispositions pour la combustion, l'air de ventilation et l'ouverture de ventilation permanente minimale requise,
doit être conforme au National Fuel Gas Code (ANSI Z223.1 / NFPA 54) et aux codes du bâtiment locaux applicables.
WARNING: This gas appliance must not be connected to a chimney fuel servicing a solid fuel burning appliance.
AVERTISSEMENT: Cet appareil à gaz ne doit pas être raccordé à un combustible
WARNING: THIS FIREPLACE IS NOT INTENDED FOR BURNING SOLID FUELS.
AVERTISSEMENT: CE FOYER N'EST PAS DESTINÉ À BRÛLER DES COMBUSTIBLES SOLIDES.
GRAND CANYON GAS LOGS • QUEMADOR BED ROCK II SIN VENTILACIÓN | 25
DO NOT REMOVE THIS LABEL
See installation & operating instructions for this model.
Contact local building officials about restrictions and
installation specifications in your area.
DATE
OF MFG.
24
36
16,000 (4.00kW)
32,000 (9.37kW)
10,000 (2.93kW)
20,000 (5.36kW)
24
36
16,000 (4.00kW)
32,000 (9.37kW)
10,000 (2.93kW)
20,000 (5.36kW)
MANIFOLD PRESSURE:
ELECTRICAL RATING: 120V/60HZ
GAS TYPE: NATURALGAS /LIQUID PROPANE
de cheminée desservant un appareil à combustible solide.
SERIAL
#
48
39,500 (11.57kW)
27,000 (7.91kW)
48
39,500 (11.57kW)
27,000 (7.91kW)
Pression au Collecteur: 2.40wPA d'une colonne d'eau (LP)
Pression d'Alimentation Min.: 2.74wPA d'une colonne d'eau (LP)
Pression d'Alimentation Max.: 3.49wPA * d'une colonne d'eau (LP)
** Pression d'alimentation maximale ne devait pas dépasser
3.49wPA. Dégagements minimaux des matériaux combustibles:
Dessus, côtés et arrière: selon les espaceurs de dégagements
pour les matériaux d'ossature selon le manuel du
propriétaire pour les matériaux de finition
TESTED &
REPORT NO.
LISTED BY:
ANSI-Z21.11.2.2016
Uncented Room Heater
ANSI-Z21 60-2017
CSA 2.26-2
Decorative gas appliances for
installation in solid-fuel
REPORT NO. #
burning fireplaces.
60
39,500 (11.57kW)
27,000 (7.91kW)
60
39,500 (11.57kW)
27,000 (7.91kW)
LP Models
Alimentation / Alimentation Réduite
Manifold Pressure: 10.5" w.c. (LP)
Minimum Supply Pressure: 11" w.c. (LP)
Max. Supply Pressure: 14"* w.c. (LP)
Élévation
P4