iNSTALLATiON iNSTruCTiONS
Installation location requirements (Cont.)
WArNiNg
w
Read all installation instructions completely before installing and operating your dryer! It is important that
you review this entire manual before installing and using your dryer. Detailed instructions concerning electrical
connections, gas connections, and exhaust requirements are provided on the following pages.
• A location that allows for proper exhaust installation.
A gas dryer must be exhausted to the outdoors. See
Venting Requirements(P.20).
• A grounded electrical outlet located within 2 ft.
(61 cm) of either side of the dryer. See Electrical
Requirements(P.24).
Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off
at the end of an automatic cycle. This can result in longer drying times. The dryer must not be installed or stored in
an area where it will be exposed to water and/or weather. Check code requirements. Some codes limit, or do not
permit, installation of the dryer in garages, closets, mobile homes or sleeping quarters. Contact your local building
inspector.
Clearances (Space for Using the Dryer.)
If the duct is installed in the wall.
(151.8 cm)
1"* (2.5 cm)
59"
• A sturdy floor to support the total dryer weight of 200
lbs (90.7 kg). The combined weight of a companion
appliance should also be considered.
• No other fuel-burning appliance can be installed in
the same closet as a dryer.
5 "**
2/4
(14 cm)
If the duct isn't installed in the wall.
81.6 "
(207.2 cm)
29"
(73.7 cm)
64"
(164.5 cm)
59"
5"
(151.8 cm)
(12.7 cm)