To a House Gas Supply Line: Option 2
• A gas supply hose and quick disconnect designed for natural gas and
certified for outdoor use are included with natural gas grills.
• Natural gas plumbing must supply a pressure of 7 inches water column
pressure to the inlet of the grill.
• Piping and valves upstream of the quick disconnect are not supplied.
• The gas pipe must be sized to supply the BTU/h specified on the rating
plate, based on the length of the piping run.
• See "WARNING! General Information" of this manual for installation codes.
1. Hook-up to a gas supply line must be performed by a licensed gas fitter
and leak tested before operating the grill.
2. Do not route the hose in close proximity to the drip pan or over top of the
back panel.
3. Ensure the hose does not contact any high temperature surfaces.
Quick Disconnect
• Do not install the quick disconnect in an upward direction.
• A readily accessible manual shut-off valve must be installed upstream of
the quick disconnect, and as close to it as possible.
• Connect the flared end of the hose to the fitting on the end of the
manifold tube or flex tube (if applicable).
• Tighten using two wrenches. Do not use thread sealer or pipe dope.
• Leak test all joints prior to operating the gas grill. See "Leak Test".
WARNING! Close the individual shutoff valve to isolate the grill from the gas supply piping system during any
pressure testing equal to or less than ½ Psi (3.5 kPa).
WARNING! Check the hose for evidence of excessive abrasion, melting, cuts or cracks. If the hose is damaged,
it must be replaced with an assembly specifically recommended by Napoleon.
Napoleon.com | Rogue® Series Grills
BE
CAREFUL!
The lid of the grill and
the entire firebox can
become very hot when
in use.
!
7
Getting Started |