Descargar Imprimir esta página

MADER APW-VQA-130P Manual Del Usuario página 34

Hidrolavadora de alta presión 2500w

Publicidad

Idiomas disponibles

Idiomas disponibles

This unit is to be connected to a cold water source
The motor of this pressure washer will NOT run, it will only operate when the trigger is squeezed.
- Connect the outlet hose to the washer and connect the spray gun to the outlet hose.
- Connect nozzle and nozzle extension.
- Check gauze filter is clear of any blockage.
- Connect the water supply hose.
- Check that the hose has no kinks in it.
- Turn on water and check for leaks.
- Depress trigger to allow air to be expelled though the pump and hoses, lock trigger.
- Plug in machine and turn on switch.
- Unlock trigger and use the pressure washer.
1.
Turn off the motor(push switch to the off position)
2.
Unplug the unit from the power source.
3.
Turn off the water supply.
4.
Press the trigger of the gun to depressurize the system.
5.
Disconnect the garden hose from the pressure washer.
6.
Wipe all surfaces of the unit with a damp clean cloth.
7.
Engage the gun safety lock.
ALWAYS turn off the unit's motor BEFORE turning off the unit's water supply.
Serious damage could occur to the motor if the unit is run without water.
NEVER disconnect the high-pressure discharge hose from the machine while the system
is still pressurized. To depressurize the unit, turn off the motor, turn off the water supply and squeeze
the trigger 2-3 times.

Publicidad

loading