Descargar Imprimir esta página

Bosch GWS Professional 15-125 CIEH Manual Original página 30

Ocultar thumbs Ver también para GWS Professional 15-125 CIEH:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
OBJ_BUCH-165-005.book Page 31 Wednesday, July 28, 2010 8:54 AM
Operation
Starting Operation
Observe correct mains voltage! The voltage
of the power source must agree with the
voltage specified on the nameplate of the
machine. Power tools marked with 230 V
can also be operated with 220 V.
When operating the machine with power from
mobile generators that do not have sufficient re-
serve capacity or are not equipped with suitable
voltage control with starting current amplifica-
tion, loss of performance or untypical behavior
can occur upon switching on.
Please observe the suitability of the power gen-
erator being used, particularly with regard to
the mains voltage and frequency.
Switching On and Off
To start the power tool, press the On/Off switch
4 forward and then down.
To lock-on the pressed On/Off switch 4, push
the On/Off switch 4 further forward.
To switch off the power tool, release the On/Off
switch 4, or when it is locked, briefly press the
On/Off switch 4 and then release it.
Switch Version without Lock-on
(country-specific):
To start the power tool, press the On/Off switch
4 forward and then down.
To switch off the machine, release the On/Off
switch 4.
Check grinding tools before using. The
grinding tool must be mounted properly
and be able to move freely. Carry out a test
run for at least one minute with no load. Do
not use damaged, out-of-centre or vibrating
grinding tools. Damaged grinding tools can
burst and cause injuries.
Bosch Power Tools
Kickback stop
In case of a sudden drop in speed,
e.g., caused by a jammed disc
while cutting, the power supply to
the motor is electronically inter-
rupted.
To restart the operation, switch the On/Off
switch 4 to the Off position and start the ma-
chine again.
Restarting Protection
The restarting protection feature prevents un-
controlled restarting of the machine after an in-
terruption in the power supply.
To restart the operation, switch the On/Off
switch 4 to the Off position and start the ma-
chine again.
Reduced starting current
The electronic reduced starting current limits
the power consumption when switching the tool
on and enables operation from a 13 ampere
fuse.
Note: When the machine runs with full speed af-
ter switching on, the reduced starting current,
the restarting protection and the kickback stop
features have failed. The power tool must
promptly be sent to an after-sales service agent
for maintenance; addresses, see Section „After-
sales Service and Customer Assistance".
Constant Electronic Control
Constant electronic control holds the speed
constant at no-load and under load, and ensures
uniform working performance.
1 609 929 X20 | (28.7.10)
English | 31

Publicidad

loading