After the last confirmation movement, the motor starts a series of UP and DOWN
movements: the first lasts 2 seconds, the next ones go max 10 seconds. To properly
associate the UP and DOWN buttons, press the button corresponding to the motor
movement for one second as indicated below:
?
REMOTE CONTROL SETTING FUNCTION
Every time you connect the power supply to the motor, you have 3 hours to store the
first remote control. After this time, the ability to store the remote control is disabled.
To reset the timer of the function you have to disconnect and reconnect the power
supply to the motor.
LIMIT SWITCHES AND OBSTACLE DETECTION
After having memorized the first remote control and properly assigned the rotation
direction, the motor is ready for operation.
Run two complete ascent and descent cycles with the A and C buttons on the remote
control to memorise the operating times and enable obstacle detection.
In the event an obstacle is detected, the motor will perform a safety movement in reverse
equal to about ¼ of the blind travel.
AUTOMATIC DISABLING OF THE FIRST
A
C
T1 (1 sec)
32
The motor stops: the UP
and DOWN buttons are
now properly associated.