Descargar Imprimir esta página

Holmatro HNC 1536 N Serie Manual página 25

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54
7.2
The High-Flow couplers fail to connect or disconnect
/i
Possible cause
The system is pressurized.
7.3
The tool does not operate at all or does not operate satisfactorily
/i
Possible cause
The High-Flow couplers are disconnected.
The pressure relief valve on the pump is in the
"neutral" position.
The hydraulic oil level in the pump is too low.
8
Maintenance
8.1
General
For standard installation instructions, refer to the Service & Support section of the Holmatro website.
Proper preventive maintenance of the equipment preserves the operational safety and extends the life
of the equipment.
WARNING
When performing maintenance activities, always comply with the relevant safety regulations.
Wear the prescribed personal protection equipment.
8.1.1
Dangerous substances
WARNING
Used or leaked fluids, and any other products consumed during the activities, must be
collected and disposed of in an environmentally responsible way.
8.2
Maintenance materials
/i
Application
Steel parts
Hydraulic couplers
Cutter
Contact the Holmatro dealer for information on spare parts.
8.3
Maintenance schedule
This schedule is an average. Depending on the intensity of use of your equipment, Holmatro can
provide a specific maintenance schedule for you.
HNC
Type of maintenance material
WD-40 preservative oil
Tectyl ML from Valvoline (long term preservation)
WD-40 preservative oil
Molykote (100.581.081)
916.219.553_003
Solution
Depressurize the system using the operating
valve.
Solution
Connect the loose High-Flow couplers.
Set the pressure relief valve on the pump in the
"operation" position.
Add the correct hydraulic oil to the pump.
EN
Amount
As required
As required
As required
As required
25

Publicidad

loading