TECHNICAL SPECIFICATIONS
Power supply (L-N)
Max motor load
Output for Vac accessories power
Device test power Vdc
Courtesy light output
Flashing light output
Pause time
Operating temperature
230 Vac power supply line fuses
Max. number of transmitters storage FIX CODE
Max. number of transmitters storage ROLLING CODE
2.4 - List of cables required
The cables required for connection of the various devices in a
standard system are listed in the cables list table.
The cables used must be suitable for the type of installation; for
ELECTRIC CABLE TECHNICAL SPECIFICATIONS
Connection
Control unit power supply line
Flashing light, courtesy light
Antenna
Electric lock
Transmitter photocells
Receiver photocells
Sensitive edge
Key-switch
* If the power supply cable is more than 20 m long, it must be of larger gauge (3x2.5mm
near the automation unit
** Two cables of 2 x 0.5 mm
2
3 - PRELIMINARY CHECKS
Before installing the product, perform the following checks and
inspections:
check that the gate, the door or the barrier is suitable for automation;
the weight and size of the gate or door and the balance of the
barrier boom must be within the operating limits specified for the
automation system in which the product is installed;
heck that the gate or door has firm, effective mechanical safety
stops;
make sure that the product fixing zone is not subject to flooding;
high acidity or salinity or nearby heat sources might cause the
product to malfunction;
in case of extreme weather conditions (e.g. snow, ice, wide
temperature variations or high temperatures), friction may
increase, causing a corresponding rise in the force needed to
operate the system;
the starting torque may therefore exceed that required in normal
conditions;
check that when operated by hand the gate, the door or the barrier
moves smoothly without any areas of greater friction or derailment
risk;
cable
1 x cable 3 x 1,5 mm
3 x 0,5 mm
**
2
1 x cable type RG58
1 x cable 2 x 1 mm
1 x cable 2 x 0,5 mm
1 x cable 4 x 0,5 mm
1 x cable 2 x 0,5 mm
1 x cable 4 x 0,5 mm
can be used as an alternative
230 Vac (+10% - 15%) 50-60 Hz
150 W
24 Vac without regulation 200 mA
24 Vdc without regulation 250 mA
24 Vdc 25 W
24 Vdc 25 W
Adjustable 0-900 sec.
-20 °C + 55 °C
1.6 A slow-acting
150 transmitters
150 transmitters
example, an H03VV-F type cable is recommended for indoor
applications, while H07RN-F is suitable for outdoor applications.
maximum allowable limit
20 m *
2
20 m
20 m (advised < 5 m)
10 m
2
20 m
2
20 m
2
20 m
2
**
20 m
2
) and a safety grounding system must be installed
2
check that the gate, door or the barrier is well balanced and will
therefore remain stationery when released in any position;
check that the electricity supply line to which the product is to be
connected is suitably earthed and protected by an overload and
differential safety breaker device;
he system power supply line must include a circuit breaker
device with a contact gap allowing complete disconnection in the
conditions specified by class III overvoltage;
ensure that all the material used for installation complies with the
relevant regulatory standards.