ENGLISH
Jandy
Smart Sync
®
Section 1. Important Safety Instructions
READ AND FOLLOW ALL INSTRUCTIONS
Specifications
• Smart Sync 60 Watt
– Rated Max Input 5.0A @ 12VAC
– Rated Max Output 4.5A @12VDC
– Controls up to 12 feet of LED waterfalls
• Only use 12VAC input power from a listed low voltage Class 2
landscape or pool/spa lighting transformer.
• Always connect the Class 2 isolated transformer in between pool
controls and Smart Sync.
• Each waterfall requires 5 watts per foot.
ATTENTION
The Jandy Smart Sync LED Adapter should only be used with Smart Sync compatible devices.
Never use in conjunction with the LED Waterfall Colorwheel Controls. Use of the Jandy Smart
Sync LED Adapter requires connection to an automation system or control switch.
SAVE THESE INSTRUCTIONS
Page 4
LED Adapter | Installation & Operation Manual
®
Jandy
Smart Sync
LED Adapter | Installation & Operation Manual
®
®
Section 2. Installation
WARNING
Risk of electric shock which can result in serious injury or death:
Before attempting to install or service, ensure that all power to the circuit supplying power
to the system is disconnected or turned off at the circuit breaker. All wiring must be done in
accordance with the National Electrical Code
Electrical Code (CEC), CSA C22.1, must be followed. All applicable local installation codes
and regulations must be followed.
2.1
Select Series
Each of the three series has a distinct color/show sequence and
matches with a different type of lighting.
1.
Determine which series to use based on the type of lighting the
Smart Sync LED Adapter will be controlling:
• Jandy
: J-Series (1)
®
• Hayward
Industries: H-Series (2)
®
• Pentair
Water Pool and Spa, Inc.: P-Series (3)
®
2.
Using a flathead screwdriver, rotate the dial on the side of the
Smart Sync LED Adapter to the corresponding number for the
series you want to select (see sticker on LED adapter).
See Figure 1.
Figure 1.
Turning dial with screwdriver
ENGLISH
®
(NEC
®
), NFPA70
®
. In Canada, the Canadian
Page 5