Commissioning and operation
78
Capstan winch 1800, 1200, 400

Starting the Active motor

In order to start the motor:
Switch the on/off switch to the "I" position.
If the motor is still cold:
Set the choke lever to the "| |" position.
If the motor has already been running and is warm, you do not
i
require the choke function.
Press the rubber dome of the primer approx. 1–2 times, to pump the
petrol mixture into the carburettor. As soon as mixture is visible in
the primer stop pumping, otherwise the motor will "flood".
The petrol mixture is visible in the primer.
Press the decompression button down.
The decompression button automatically springs back into its
original position after first ignition.
Vigorously pull the starter handle one time only!
Only pull the starter handle once whilst the choke lever is in the
i
"|   |" position. Otherwise there is a risk that the fuel will flood
the cylinder and the motor will be more difficult to start. In this
case, set the choke lever to the "|  |" position and repeat the
start process. If the motor still fails to start, clean the spark plug
and repeat the start process after approx. 20-30 min.