Descargar Imprimir esta página

Cafe CVE Serie Manual Del Propietario E Instrucciones De Instalación página 45

Ocultar thumbs Ver también para CVE Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

Performance Data Sheet
Model: GE Appliances XWFE
performance data sheet and at iapmort.org.
Substance Tested for Reduction
Chlorine Taste and Odor
Chloramine Taste and Odor
Particulate, Class I
Cysts
Lead
Mercury
Asbestos
Toxaphene
VOC (Chloroform surrogate chemical)
Alachlor
Carbofuran
carbon tetrachloride
chloropicrin
2,4-D
dibromochloropropane (DBCP)
1,2-dichloroethane
1,1-dichloroethylene
cis-1,2-dichloroethylene
trans-1,2-dichloroethylene
1,2-dichloropropane
cis-1,3-dichloropropylene
dinoseb
Endrin
ethylene dibromide (EDB)
bromochloroacetonitrile
dibromoacetonitrile
dichloroacetonitrile
trichloroacetonitrile
1,1-dichloro-2-propanone
1,1,1-trichloro-2-propanone
heptachlor (H-34, Heptox)
heptachlor epoxide
hexachlorobutadiene
hexachlorocyclopentadiene
Lindane
methoxychlor
pentachlorophenol
Styrene
1,1,2,2-tetrachloroethane
Tetrachloroethylene
Toluene
2,4,5-TP (silvex)
tribromoacetic acid
1,1,1-trichloroethane
1,1,2-trichloroethane
trichloroethylene
bromoform
bromodichloromethane
chlorodibromomethane
xylenes
Meprobamate
Atenolol
DEET
Metolachlor
Trimethoprim
Linuron
TCEP
TCPP
Phenytoin
Ibuprofen
Naproxen
Estrone
Bisphenol A
Nonyl phenol
49-1000329 Rev. 4
Influent challenge
Maximum permissible
concentration
product water
(mg/L)
concentration (mg/L)
2.0 mg/L +/- 10%
N/A
3.0 mg/L +/- 10%
0.5
At least 10,000/mL
N/A
50,000/L
N/A
0.15
0.01
0.006
0.002
107 to 108 fibers/ L
N/A
0.015 +/- 10%
0.003
0.300
0.015
0.050
0.001
0.100
0.003
0.081
0.001
0.190
0.001
0.078
0.0018
0.077
0.001
0.015
0.0002
0.110
0.0017
0.052
0.00002
0.08
0.001
0.040
0.001
0.088
0.0048
0.083
0.001
0.170
0.0005
0.086
0.001
0.080
0.001
0.079
0.001
0.170
0.0002
0.053
0.00059
0.088
0.001
0.044
0.00002
0.022
0.0005
0.024
0.0006
0.0096
0.0002
0.015
0.0003
0.0072
0.0001
0.0082
0.0003
0.025
0.00001
0.0107
0.0002
0.044
0.001
0.060
0.000002
0.055
0.00001
0.050
0.0001
0.096
0.001
0.120
0.004
0.150
0.0005
0.081
0.001
0.081
0.001
0.078
0.001
0.270
0.0016
0.042
0.001
0.160
0.0005
0.084
0.0046
0.150
0.0005
0.180
0.0010
0.300
0.015
0.300
0.015
0.300
0.015
0.070
0.001
400 +/- 20%
60
200 +/- 20%
30
1400 +/- 20%
200
1400 +/- 20%
200
1400 +/- 20%
200
140 +/- 20%
20
140 +/- 20%
20
5000 +/- 20%
700
5000 +/- 20%
700
200 +/- 20%
30
400 +/- 20%
60
140 +/- 20%
20
140 +/- 20%
20
2000 +/- 20%
300
1400 +/- 20%
200
Avg %
Application Guidelines/Water Supply Parameters
Reduction
Service Flow
96.9
Water Supply
96.9
Water Pressure
91.4
Water Temperature
>99.99
Capacity
98.85
96.3
It is essential that the manufacturer's recommended installation,
>99
maintenance and filter replacement requirements be carried out for the
86.95
product to perform as advertised. See Installation Manual for Warranty
99.7
information.
> 98
NOTE: While the testing was performed under standard
> 97
> 99
laboratory conditions, actual performance may vary.
> 99
Replacement Cartridge: XWFE. For estimated costs
98
of replacement elements please visit our website at
> 99
cafeappliances.com.
99
98
> 99
WARNING
> 99
> 98
• Do not use with water that is microbiologically unsafe
95
or of unknown quality without adequate disinfection
> 99
before and after the system. Systems certified for cyst
> 99
reduction may be used on disinfected water that may contain
> 99
filterable cysts.
> 99
> 99
99
NOTICE
99
To reduce the risk of water leakage or flooding, and to
> 99
ensure optimal filter performance:
> 99
• Read and follow use instructions before installation and
98
use of this system.
98
98
• Installation and use MUST comply with all state and local
98
plumbing codes.
99
• Do not install if water pressure exceeds 120 psi (827
96
kPa). If your water pressure exceeds 80 psi (552 kPa), you
>99
must install a pressure-limiting valve. Contact a plumbing
98
professional if you are uncertain how to check your water
> 98
> 99
pressure.
> 99
• Do not install where water hammer conditions may occur.
> 99
If water hammer conditions exist you must install a water
> 99
hammer arrester. Contact a plumbing professional if you are
> 97
uncertain how to check for this condition.
> 99
• Do not install on hot water supply lines. The maximum
> 99
operating water temperature of this filter system is 100º F
> 99
> 99
(38º C).
99
• Protect filter from freezing. Drain filter when temperatures
> 98
drop below 33ºF (0.6ºC).
> 99
• Change the disposable filter cartridge every six months or
95
sooner if you observe a noticeable reduction in water flow
> 99
rate.
> 99
• Failure to replace the disposable filter cartridge at
95
95
recommended intervals may lead to reduced filter
95
performance and cracks in the filter housing, causing water
>99
leakage or flooding.
95.5
• This System has been tested according to NSF/ANSI 42,
95.9
53, 401, and P473 for the reduction of the substances listed
98.6
below. The concentration of the indicated substances in
98.6
98.7
water entering the system was reduced to a concentration
96.1
less than or equal to the permissible limit for water leaving
96.6
the system, as specified in NSF/ANSI 42, 53, 401, and P473.
98.1
98.1
96
95.9
96.5
97.1
99.1
97.3
0.5 gpm (1.89 lpm)
Potable Water
25-120 psi (172-827 kPa)
33°F-100°F (0.6°C-38°C)
170 gallons (643.5 liters)
To reduce the risk associated with
ingestion of contaminants:
XWFE System is certified by IAPMO
R&T against NSF/ANSI Standards 42,
53, 401, and P473 for the reduction of
claims specified on the performance
data sheet and at iapmort.org.
45

Publicidad

loading

Este manual también es adecuado para:

Cqe serie