Descargar Imprimir esta página

Selco Genesis 2200 PMC Instrucciones De Uso página 48

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 117
Passing one of the warning limits causes a visual signal to appear
on the control panel.
Passing one of the alarm limits causes a visual signal to appear
on the control panel and the immediate blockage of the weld-
ing operations.
It is possible to set start and end of welding filters to prevent
error signals during the striking and extinction of the arc (consult
the "Set up" section - Parameters 802-803-804).
3.13 Alarms screen
Allows the intervention of an alarm to be indicated and provides
the most important indications for the solution of any problem
encountered.
1
Alarm icon
2
Alarm code
3
Alarm type
Alarm codes
E01, E02 Temperature alarm
It is advisable not to switch off the equipment while the alarm
is on; the internal fan will thus keep operating and will help to
cool the overheated parts.
E07
Wire feed motor supply alarm
E08
Blocked motor alarm
E10
Power module alarm
E13
Communication alarm
48
E19
System configuration alarm
E20
Memory fault alarm
E21
Data loss alarm
E40
System power supply alarm
E43
Coolant shortage alarm
Guard limits code
E54
Current level exceeded (Alarm)
E62
Current level exceeded (Warning)
E55
Current level exceeded (Alarm)
E63
Current level exceeded (Warning)
E56
Voltage level exceeded (Alarm)
E64
Voltage level exceeded (Warning)
E57
Voltage level exceeded (Alarm)
E65
Voltage level exceeded (Warning)
E74
Motor 1 current level exceeded (Warning)

Publicidad

loading