Modbus parti-
A maximum of 4 Modbus stations can be connected to the Modbus connection
cipant - Fronius
terminal.
SnapINverter
IMPORTANT!
Only one primary meter, one battery and one Ohmpilot can be connected per in-
verter. Due to the high data transfer of the battery, the battery occupies 2 sub-
scribers.
Example:
Multi meter sys-
If several Fronius Smart Meters are installed, a separate address must be set for
tem - Fronius
each one (see
SnapINverter
primary meter always receives the address 1. All other meters are numbered
Generator meter
records the load curve of individual generators (e.g. wind power
plant) in the consumption branch and makes the measured data
available for energy profiling in Fronius Solar.web.
Modbus RTU slave
e.g. Fronius Ohmpilot, Fronius Solar Battery, etc.
Loads in the system
e.g. washing machine, lights, television, etc.
Additional loads in the system
e.g. heat pump
Additional producers in the system
e.g. wind power plant
Termination resistance
R 120 Ohm
Input
Battery
Set the address of the Fronius Smart Meter
Number
Fronius
of primary
Ohmpilot
meters
1
1
1
1
Number
of secondary
meters
0
1
2
3
on page 15). The
19