Step 1
Check of the roof angle
- Use the template to check the angle of the roof.
- Fit the template to the roof on the right or left side of the unit.
- Position the start of the level perfectly in line with that of the template so as to create
a hinge point.
- Lift the level from the opposite side until it reads 0.
- Read the angle of the roof on the template and compare it with the information in this
calibration so as to find the amount of water that needs to reach the container.
DEGREES
TEMPLATE
VEHICLE ROOF
Calibration table
Angle degrees
From 0° to 3°
From 3° to 15°
Step 2
Solenoid opening time
The important part of this stage is to set the opening time for the solenoid, so as to
allow the exact amount of water to the basin, as set beforehand according to the slant
of the roof and in line with the table.
Date 11.09.2020
MEETING POINT
Amount of
water
1,5 liter
1,0 liter
• Remove the cover from the unit.
• Remove the water delivery pipe, without the bend fitting, and insert it into the
graduated container.
Step 3
Software configuration
Switch off the display completely.
Simultaneously hold down the OK key
plus low arrow until you hear the beep
(about 20 seconds will pass)
8