Descargar Imprimir esta página

ULTIMATE SPEED UMAP 12000 B2 Instrucciones De Funcionamiento Y De Seguridad página 18

Ocultar thumbs Ver también para UMAP 12000 B2:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 180
2. First connect
the red clamp
(A) to the
positive pole
of the vehicle
battery and
then connect the
black battery
clamp (B) to the
negative pole
(see Fig. 1).
3. Starting up
the vehicle.
1
18
GB/IE/NI/CY/MT
The red Error
13
LED
flashes,
a short alarm
signal sounds.
The red Error
13
LED
flashes,
a continuous
alarm signal
sounds.
The red Error
13
flashes
LED
once, a
continuous alarm
is sounded and
then followed by
two short alarm
sounds.
Green Start LED
12
and the red
13
Error LED
flash alternately.
B
2.
The temperature
is too high,
possibly due to
several jump
start attempts.
Battery clamps
(A) and (B)
are the wrong
way round. It
is caused by a
short circuit or
the battery is
leaking.
The connection
is correct After
1–2 seconds
only the green
12
LED
glows.
A
1.
Disconnect
the black (B)
battery clamp
first and then
the red clamp
(A) from the
battery poles.
Start again
from step 1.
Carry on with
step 3.

Publicidad

loading