Descargar Imprimir esta página

Berner 369543 Instrucciones De Manejo página 5

Ocultar thumbs Ver también para 369543:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
CAUTION: Constant air rates vary depending on the size and power of the compressor.
Always make sure that the tank and the air hoses are free of impurities of any kind.
EXPLANATION OF THE PICTOGRAMS:
Always use hearing protection, face and eye-protection, dusk-mask, if necessary a hair-net,
protective gloves and read / understand the instruction manual.
TECHNICAL DATA
Air inlet
Air pressure / max. pressue
Air consumption
Weight
A weighted emission sound pressure level at the
operators position in decibel (LpA)
Measurement accuracy (KpA)
A weighted sound power level in decibel (LwA)
Measurement accuracy (KpA)
Peak C-weighted instantaneous sound pressure
level at workstation (LpC)
Measurement accuracy (KpA)
Vibration level
Measurement accuracy (Standard)
Serial number
1/4"
6.2 bar (90PSI) / 9.2 bar (133 PSI)
188 L/min
0,67 Kg
79 dB (EN ISO 15744:2002) ISO 4871:1996
ISO 3744:2010, ISO 11203:1995
3 dB
90 dB (EN ISO 15744:2002) ISO 4871:1996
ISO 3744:2010, ISO 11203:1995
3 dB
96 dB (EN ISO 15744:2002) ISO 4871:1996
ISO 3744:2010, ISO 11203:1995
3 dB
0.09 m/sec² (ISO 20643:2005/Amd. 1:2012)
0.02 m/sec² (ISO 20643:2005/Amd. 1:2012)
EN

Publicidad

loading

Este manual también es adecuado para:

Bpt-tg b011